期刊文献+

珠江电厂300MW机组给水泵小汽机润滑油含水改造

Improvement of the Water Contained in Lube Oil of Feedwater Pump Turbine for 300 MW Power Unit in Zhujiang Power Plant
下载PDF
导出
摘要 该文分析了小汽机润滑油中轴封漏气导致大量含水的原因,提出改进措施。经改造实施,机组运行证明,2 号机组B给水泵小汽轮机润滑油含水率显著下降,符合生产标准。提高了机组运行的安全性和经济性,并在该厂其它机组上得到推广。 Reasons of water contained in the lube oil of feedwater pump turbine have been analyzed because of shaft gland leakage in the asticle. The countermeasures have also been put forward. The rate of water countained in BFPT lube oil of No. 2 unit has obviously been decreased based on improvement and operation which being in conformity with production standard. The safety and economy have been in creased during operation.
出处 《电站辅机》 2005年第4期34-36,共3页 Power Station Auxiliary Equipment
关键词 给水泵小汽轮机 润滑油 含水率 经济性 BFPT lube oil the rate of containing water economy