期刊文献+

下肢二维TOF法磁共振血流成像

Two-Dimensional Time-of-Flight MR Angiography of the Lower Extremity Arteries
下载PDF
导出
摘要 本文目的是确定二维TOF法磁共振血流成像对下肢周围血管性疾病诊断的准确性和可靠性。15例患者132段血管用二维TOF法磁共振血流成像检查,其中6例患者49段血管同时进行了常规血管造影检查。在132段血管中,MRA检查显示正常血管102段,异常血管30段。在30段异常血管中,轻度狭窄9段,明显狭窄11段,完全闭塞8段,动脉瘤2段。在同时进行MRA和常规血管造影检查的49段血管中,正常血管35段,异常血管14段。二者显示一致47段,仅2段显示有差异,其中1段是由于动脉内Strecker支架置入引起MRA信号丢失,考虑血管闭塞,而血管造影显示血管明显狭窄。另一段MRA显示一侧髂总动脉轻度狭窄,而血管造影正常。我们的研究结果证明MRA对下肢周围血管性疾病,特别是闭塞性血管疾病有较高准确性和可靠性。如能适当应用扫描序列和参数,将使其能达到常规血管造影对周围血管性疾病诊断的精确性。 To identify the accuracy and reliability of magnetic resonance angiography (MRA) in evaluating patients with lower peripheral vascular disease. Two-dimensional time-of-flight (2D TOF) MRA was used to evaluate 132 arterial segments in patients. Of which, 49 segments in six patients were studied with conventional arteriography. MRA findings were compared with that of the angiography. In 132 segments, MRA showed normal in 102 comfirmed by angiographies in all 35 undergoing arteriographies, and abnormal in 30 (mild stenosis in nine. significant stenosis in 11, occlusions in eight, and aneurysms in two) identified by angiographies in 14. In the 49 segments e valuated by both MRA and angiography, a good correlation between these two imaging modalities was found in 47 of the 49 segments, and a poor correlation in two because of loss of blood flow on the MR angiogram after implantation of a Strecker stent in one, of technical limitation in another one. 2D TOF MRA is accurate and reliable in evaluating the patency of the lower extremity arteries.
出处 《中国医学影像技术》 CSCD 1996年第2期89-92,共4页 Chinese Journal of Medical Imaging Technology
关键词 下肢疾病 周围血管性疾病 NMR Magnetic resonance angiography Peripheral vascular disease Arterial stenosis or occlusion
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部