根据最大节约网损的原则,采用半动态的机制来确定待补偿点的位置和个数,从而减小了遗传算法的搜索空间,极大地提高了无功优化的速度和解的质量.实例验算结果表明,此方法能成功解决配电网无功优化的实际问题.
This paper introduce the half-dynamic mechanism to determine the candidate locations for the capacitors. The objective is to minimize the energy losses and power losses in the distribution system considering, at the same time, in order to decrease the searching space of GA and increase the convergence speed. Test result has been presented along with the discussion of the algorithm. The tests, 33-node feeder prove the correctness and efficiency of the method.
出处
《西安工程科技学院学报》
2005年第4期436-439,共4页
Journal of Xi an University of Engineering Science and Technology
关键词
配电网
无功优化
遗传算法
有功网损
distribution network
reactive power optimization
genetic algorithm
active power loss