摘要
运用等管径条件下的油品顺序输送混油长度计算公式,依据混油等容积原理,推导出顺序输送串联管路 (即不同管径)逐次符合上一段管径条件下的管路当量长度,进而得到整个管路的混油长度的计算公式。
By using the formula to calculate the interface length in series sequence transportation pipeline under equal pipe diameter, the equivalent pipeline length of series sequence transportation pipeline ( different pipe diameters) which accords with the diameter of the upper pipeline section by section is derived based on the interface principle of equivalent volume and, then the formula to calculate the interface length in whole pipeline is obtained.
出处
《炼油技术与工程》
CAS
北大核心
2006年第1期49-51,共3页
Petroleum Refinery Engineering
关键词
顺序输送
串联管路
混油
计算方法
sequence transportation, series pipeline, calculation method