期刊文献+

基于固定采样频率的相量精确测量算法 被引量:7

Study on the precise phasor calculation based on constant sampling frequency
下载PDF
导出
摘要 离散傅里叶(DFT)算法是电网实时运行系统中进行相量测量的基本算法.由于相量测量装置(PMU)对相量测量同步性的要求,其采样频率应保持为常数,当系统频率变化时,相量的计算会出现误差.笔者分析了采样频率固定而系统频率发生偏移时的相量测量误差的变化规律,指出相角的测量误差与数据窗中相量参考点的选择有关,并提出一种利用系统频率对相量进行校正的新方法.仿真实验的结果表明,该方法可以使相量的测量误差大大降低. Discrete fourier transform (DFF) is the basic method for measuring the phasor of power system in real-time. The sampling frequency of PMU is constant because of the synchronization of its phasor measuring. As system frequency changes, the error of measuring phasor is avoidless. In this paper the variation of measurement error is analyzed and the relation between error of angle and the selection of reference point in the data window summarized. A new method to revise the phasor by the measuring frequency is presented. Simulation result shows that the measuring error of magnitude and angle can reduce greatly using this method.
出处 《山东大学学报(工学版)》 CAS 2005年第6期46-49,117,共5页 Journal of Shandong University(Engineering Science)
关键词 相量测量 离散傅里叶变换 测量误差 频率校正 phasor measuring DFr measure ment error frequency correction
  • 相关文献

参考文献9

  • 1NGUYEN C T,SRINIVASAN K.A new technique for rapid tracking of frequency deviations based on level crossings[J].IEEE Transactions on Power Apparatus and Systems,1984,103(8):2230-2236.
  • 2TERZIJA V V,DJURIC M B,KOVACEVIC B D.Voltage phasor and local system frequency estimation using Newton type algorithm[J].IEEE Transactions on Power Delivery,1994,9(3):1368-1374.
  • 3SACHDEV M S,WOOD H C,AND JOHNSON N G.Kalman filtering applied to power system measurements for relaying[J].IEEE Transactions on Power Apparatus and System,1985,104(12):3565-3573.
  • 4GIRGIS A A,HWANG T L D.Optimal estimation of voltage phasors and frequency deviation using linear and nonlinear Kalman filter:theory and limitations [J].IEEE Transactions on Power Apparatus and Systems,1984,103(10) :2943-2949.
  • 5WANG A D,GE Y Z,LAI L L,et al.A new digital algorithm for power system frequentcy measurements [A].lEE 2nd International Conference on Advance inPower System Control,Operation and Management[C].Hong Kong:IEE Press,1993.729-733.
  • 6许庆强,索南加乐,宋国兵,施静辉,葛耀中.振荡时电力系统瞬时频率的实时测量[J].中国电机工程学报,2003,23(1):51-54. 被引量:29
  • 7ZHOU Jie,ZHANG Chang-yin,HE Wei,et al.Power system technology[J].Proceedings of Power Conference,2002,(3):1947-1951.
  • 8杨贵玉,江道灼,邱家驹.相角测量装置的同步测量精度问题[J].电力系统自动化,2003,27(14):57-61. 被引量:35
  • 9IEEE Std 1344-1995,IEEE standard for synchrophasors for power systems[S].

二级参考文献12

  • 1索南加乐,葛耀中,王安定,田怀智,阿不力孜.一种不受电压过零点影响的新型频率测量方法[J].西安交通大学学报,1995,29(3):84-87. 被引量:13
  • 2电力系统稳定性专门委员会.电力系统稳定问题与决策(Power System Stability Problems & Strategies)[M].北京:水利电力出版社(Beijing:Hydraulic and Electric Power Press),1994..
  • 3Williams A B喻春轩 等译.电子滤波器设计手册(Electronic Filter Design Handbook)[M].北京:电子工业出版社(Beijing:Publishing House of Electronics Industry),1986..
  • 4[7]葛耀中(Ge Yaozhong).新型继电保护与故障测距原理与技术(New Types of Protective Relaying and Fault Location Their Theory and Techniques)[M].西安:西安交通大学出版社(Xi'an: Xi'an Jiaotong University Press),1996.
  • 5[2]朱声石(Zhu Shengshi).高压电网继电保护原理与技术(Principles and techniques of protective relaying of high-voltage eletric power network)[M].北京:中国电力出版社(Beijing:China Electricity Press),1995.
  • 6[3]Giray M M,et al. Off-nominal frequency measurements in electric power systems[J]. IEEE Trans. on PWRD ,1989,4(3):1573-1578.
  • 7[4]Kezunovic M,et al. New digital signal processing algorithm for frequency deviation measurement[J]. IEEE Trans.on PWRD, 1992,7(3):1563-1573.
  • 8[5]Sidhu T S,et al. An iterative technique for fast and accurate measurement of power system frequency[J]. IEEE Trans. on PWRD, 1998,13(1):109-115.
  • 9Power System Relaying Committee of the IEEE Power Engineering Society. IEEE Std 1344--1995. IEEE Standard for Synchrophasors for Power Systems.
  • 10杨鹏,史旺旺.电力系统微机保护中开平方浮点算法的改进[J].电力自动化设备,2000,20(1):7-8. 被引量:7