Seismic Analysis of Shear-Wall Structures with Vertically Installed Dampers

Seismic Analysis of Shear-Wall Structures with Vertically Installed Dampers
下载PDF
导出
摘要 Shear-wall structures are quite common in seismic areas because of their successful seismic behavior during severe earthquakes. But shear walls are prone to brittle failure. This study proposes a new method of vertically installed dampers (VID) to reduce the vibration in shear-wall structures. The motion characteristic of a vertical damping system is that every mass has horizontal and rotational displacements simultaneously, The establishment of dynamic equations should take into account the equilibrium conditions of both horizontal and rotational vibrations. Dynamic equilibrium equations of VID systems are derived from a model of a structure with VID. An example shear-wall structure, with and with- out VID, is studied. There are some changes in the characteristics of the maximum horizontal displacement response. Without dampers, the relative displacements between different floors in the shear wall increase with height. With dampers, the relative displacements are more uniformly distributed, and lateral displacements at the top and at the bottom are closer. When the damping coefficient is 1 000 kN · s/ m, the numerical results reveal that the maximum horizontal displacement and the maximum rotational displacement of the top floor have reduced by 59.3 % and 54.8 % respectively. Shear-wall structures are quite common in seismic areas because of their successful seismic behavior during severe earthquakes. But shear walls are prone to brittle failure. This study proposes a new method of vertically installed dampers (VID) to reduce the vibration in shear-wall structures. The motion characteristic of a vertical damping system is that every mass has horizontal and rotational displacements simultaneously, The establishment of dynamic equations should take into account the equilibrium conditions of both horizontal and rotational vibrations. Dynamic equilibrium equations of VID systems are derived from a model of a structure with VID. An example shear-wall structure, with and with- out VID, is studied. There are some changes in the characteristics of the maximum horizontal displacement response. Without dampers, the relative displacements between different floors in the shear wall increase with height. With dampers, the relative displacements are more uniformly distributed, and lateral displacements at the top and at the bottom are closer. When the damping coefficient is 1 000 kN · s/ m, the numerical results reveal that the maximum horizontal displacement and the maximum rotational displacement of the top floor have reduced by 59.3 % and 54.8 % respectively.
出处 《Journal of China University of Geosciences》 SCIE CSCD 2005年第4期349-353,共5页 中国地质大学学报(英文版)
关键词 shear wall DAMPER dynamic equilibrium equation seismic response. shear wall, damper, dynamic equilibrium equation, seismic response.
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部