A Biomimetic Hip Joint Simulator and its Application in in vitro Study of the Integrity of Replacement Cemented Hip 被引量:2

A Biomimetic Hip Joint Simulator and its Application in in vitro Study of the Integrity of Replacement Cemented Hip
下载PDF
导出
摘要 A biomimetic hip joint simulator that can be used to evaluate the outcome of the cemented total hip replacement has been designed, manufactured and evaluated. The simulator produces motion in the extension/flexion plane, with a socket to rotate internal/externally. At the same time a dynamic loading cycle is applied. A validation test was performed on a cemented femoral stem within a novel composite femur. The hone quality has a strong effect on the stem migration and on the integrity of the interfaces. The migration of the stem is a combination of 3-D translation and rotation of the stem. Under the same loading conditions, weak bone allows more stem migration than strong bone. There is a great decrease in the strength of the stem-cement interface after the dynamic test, and the weak bone composite exhibited a greater reduction in interfacial strength than the strong bone composite. The decrease of the interfacial strength indicates that the primary bonding between the stem and the cement mantle had deteriorated and the integrity of stem-cement interface was damaged. The study demonstrates the value of using a hip joint simulator to investigate stem migration and interface integrity within the cemented hip replacement, suggesting that method can be used for in vitro evaluation of the biomaterials used in the cemented hip replacements. A biomimetic hip joint simulator that can be used to evaluate the outcome of the cemented total hip replacement has been designed, manufactured and evaluated. The simulator produces motion in the extension/flexion plane, with a socket to rotate internal/externally. At the same time a dynamic loading cycle is applied. A validation test was performed on a cemented femoral stem within a novel composite femur. The hone quality has a strong effect on the stem migration and on the integrity of the interfaces. The migration of the stem is a combination of 3-D translation and rotation of the stem. Under the same loading conditions, weak bone allows more stem migration than strong bone. There is a great decrease in the strength of the stem-cement interface after the dynamic test, and the weak bone composite exhibited a greater reduction in interfacial strength than the strong bone composite. The decrease of the interfacial strength indicates that the primary bonding between the stem and the cement mantle had deteriorated and the integrity of stem-cement interface was damaged. The study demonstrates the value of using a hip joint simulator to investigate stem migration and interface integrity within the cemented hip replacement, suggesting that method can be used for in vitro evaluation of the biomaterials used in the cemented hip replacements.
出处 《Journal of Bionic Engineering》 SCIE EI CSCD 2005年第4期177-185,共9页 仿生工程学报(英文版)
关键词 hip joint simulator stem migration interface failure hip replacement BONE hip joint simulator, stem migration, interface failure, hip replacement, bone
  • 相关文献

参考文献12

  • 1C. Liu,S. M. Green,N. D. Watkins,P. J. Gregg,A. W. McCaskie.Creep behavior comparison of CMW1 and palacos R-40 clinical bone cements[J].Journal of Materials Science: Materials in Medicine.2002(11)
  • 2C. Liu,S. M. Green,N. D. Watkins,P. J. Gregg,A. W. McCaskie.Effect of restraint on the creep behavior of clinical bone cement[J].Journal of Materials Science Letters.2002(12)
  • 3Yetkinler D N,Litsky AS.Viscoelastic Behaviour of Acrylic Bone Cements[].Biomaterials.1998
  • 4Verdonschot N,Huiskes R.Creep Bahaviour of Hand-mixed SimplexK-P Bone Cement Under Cyclic Tensile Loading[].Journal ofApplied Biomaterials.1994
  • 5Norman TL,Kish V,Blaha J D,Gruen TA,Hustosky K.Creep Characteristics of Hand Mixed and Vacuum Mixted Acrylic Bone Cement at Elevated Stress Levels[].Journal of Biomechanics.1995
  • 6Loudon J R,Older M W J.Subsidence of the Femoral Component Related to Long-term Outcome of Hip Replacement[].Journal ofBone and Joint Surgery.1989
  • 7Kiss J,Murray D W,TurnerSmith A R,Bulstrode C.Migration of Cemented Femoral Components after THR-Roentgen Stereophotogrammetric Analysis[].Journal ofBone and Joint Surgery.1996
  • 8Oh I,Harris W H.Proximal Strain Distribution in the Loaded Femur[].Journal ofBone and Joint Surgery.1978
  • 9Verdonschot N,Huiskes R.Dynamic Creep Behaviour of Acrylic Bone Cement[].Journal of Biomechanics.1995
  • 10Marmor L.Femoral Loosening in Hip Replacement[].Clinical Orthopaedics.1976

同被引文献8

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部