期刊文献+

地源热泵在广东地区空调工程中应用可行性分析 被引量:7

Feasibility about the Application of Ground Source Heat Pump to Air-conditioning Engineering in Guangdong
下载PDF
导出
摘要 分析计算了广州市自然气候环境、土壤状况和介质温度,对多种形式的地源热泵空调系统在广东地区应用的条件和可行性进行了分析,提出单一地源热泵空调技术并不适合广东地区使用,广东地区应因地制宜开展地源热泵空调组合技术研究。 This paper introduces the principles of the ground source heat pump air- conditioning technology, and then analyzes and calculates the natural climate environment, soil status and medium temperature in Guangzhou. Also analyzes the application condition and feasibility of several types of ground source heat purap air- conditioning systems in Guangdong, it is suggested that developing the investigation of the ground source heat pump air- conditioning combination technology instead of only using single technology is suitable to Guangdong.
出处 《制冷》 2005年第4期66-70,共5页 Refrigeration
关键词 地源热泵 空调 节能 Ground source heat pump, Air- conditioning, Energy saving
  • 相关文献

参考文献4

  • 1Rybach,L and Sanner,B.Ground-source heat pump systems-the European experience.Geo-Heat Center Quarterly Bulleyin Klamath Falls.Oreg.Oregon Institute of Technology 2000,21 (1):16-26.
  • 2姜宝成,王永镖,李炳熙.地源热泵的技术经济性评价[J].哈尔滨工业大学学报,2003,35(2):195-198. 被引量:40
  • 3.夏热冬暖地区土壤源热泵空调系统经济分析[C]..第七届海峡两岸制冷空调技术交流会论文集[C].中国制冷学会,2005-4..
  • 4曲云霞,张林华,方肇洪,李安桂.地源热泵名义工况探讨[J].西安建筑科技大学学报(自然科学版),2003,35(3):221-225. 被引量:20