摘要
大武口电厂2004年度#1、#2炉大修期间首次在燃烧区水冷壁上发现大量的表面横向裂纹,经过对比、查阅,结合锅炉自身的燃烧状况进行综合分析,提出相应的预防治理措施。
Aims at first find out a lot of landscape orientation surface flaw on the water-cooled wall pipe in boiler burning area during ^#1,^#2 boiler heavy repair in 2004, analyzes the boiler burning status, bring forward relevant prevention and disposal measure.
出处
《宁夏电力》
2005年第C00期200-204,共5页
Ningxia Electric Power
关键词
燃烧区水冷壁管
表面裂纹
原因分析
预防治理
burning area
water-cooled wall pipe
surface flaw
cause analysis
prevention and disposal