摘要
针对长治市某厂房电镀车间鉴定中混凝土结构钢筋锈蚀状况及其损坏特征,分析其腐蚀机理,提出了防治对策,并对侵蚀后的加固处理方案进行探讨。
According to condition of corrosion and breakage of ferroconcrete structure in electric plating plant, it analyzes its mechanism and puts forward prevention measures, then discusses reinforcing plan after corrosion.
出处
《山西建筑》
2006年第2期152-153,共2页
Shanxi Architecture
关键词
钢筋锈蚀
裂缝
防府
加固
corrosion of steel bar, crack, mitigate corrosion, reinforce