摘要
为了改进以硅胶为载体的联吡啶钌对氧的响应灵敏度,采用了掺杂镧离子的硅胶做载体来固定敏感物质[Ru(bpy)3]Cl2,发现掺杂镧后样品对氧的响应倍数(I0/I)从4.6倍增大到14.4倍,响应曲线符合Stern-Volmer方程;重现性和稳定性良好;响应时间约10 s。该实验结果为发展氧传感器敏感物质的固定方法提供了一条新途径。
In order to improve the sensitivity of the oxygen sensor based on tris(2,2' - bipyridine) ruthenium ( Ⅱ) and [ Ru(bpy)]Cl2 adsorbed onto silica particles, the La - codoped silica gel was used as the support system. Compared with reference ( Io/I = 4.6), The new oxygen sensor shows a high sensitivity to oxygen with a ratio of Io/I = 14.4. The response accords with Stern - Volmer equation and the codoped sample has good repeatability and photostability, with response time approximately 10 s. This is a new approach to immobilize oxygen-sensitive material for oxygen sensor.
出处
《四川大学学报(工程科学版)》
EI
CAS
CSCD
北大核心
2006年第1期72-75,共4页
Journal of Sichuan University (Engineering Science Edition)
基金
西南科技大学青年预研基金资助项目(ZK043002)
关键词
镧离子掺杂
硅胶
联吡啶钌
氧传感器
La- codoped silica gel
support system
Ru(bpy)3^2+
oxygen sensor