酮苯装置立式氨用海水冷凝器改造 被引量:1

Improvement of vertical ammonia-seawater condenser used in acetone-benzol plant
下载PDF
导出
摘要 介绍了酮苯装置立式氨用冷凝器的失效情况,确定了海水局部腐蚀是冷凝器失效的主要原因。通过比较海军铜、钛材和奥氏体不锈钢的性能特点,选用316L不锈钢作为16Mn管板的复合层,增加了阴极保护措施,结合防海水腐蚀涂层,很好地解决了氨用海水冷凝器的海水腐蚀问题。 The corrosion failure of vertical ammonia-seawater condenser used in acetone-benzol plant was introduced. It is determined that the main failure reason is caused by seawater local corrosion. Comparing their properties among admiralty brass, titanium plate and austenite stainless steel, it is suggested that the stainless steel 316L is selected to be clad with tube-sheet 16Mn (forged steel). In addition, cathode protection is used as a new measure. Combining corrosion resistant coating, the problem of seawater corrosion failure is solved completely.
出处 《石油化工设备》 CAS 2006年第1期84-86,共3页 Petro-Chemical Equipment
关键词 冷凝器 海水腐蚀 奥氏体不锈钢 condenser seawater corrosion ammonia austenite stainless steel
  • 相关文献

参考文献8

二级参考文献17

  • 1顾根福.第九章 防污剂(二)[J].涂料工业,1993,23(1):50-53. 被引量:1
  • 2鹿守本.海水资源.中国自然资源丛书(海洋卷)[M].北京:中国环境科学出版社,1995.168.
  • 3化学工业部研究院.腐蚀与防护手册--耐蚀金属材料及防蚀技术[M].北京:化学工业出版社,1993.92.
  • 4周国定.热力设备金属腐蚀与防护[M].上海电力学院,1986..
  • 5窦昭英.电力工业的腐蚀与防护[M].化学工业出版社,1995..
  • 6武汉水利电力大学.热力发电厂水处理(下册)[M].水利电力出版社,1977..
  • 7K. suzuki, Y. nakamo. Experience with titanitun, heat exchangers in oil refineries. Materials performance, 1981 (6) : 23 - 26.
  • 8佐藤史郎.钛管在热交换器上的应用[J].石油学会志,1977,20(11):985-985.
  • 9顾根福.第六章 防污剂(一)[J]涂料工业,1992(05).
  • 10刘会山.防止凝汽器铜管氨腐蚀的措施[J].河北电力技术,1990(5):38-40. 被引量:1