采用无因次化方法将脉冲放电过程中4-氯酚的降解率及其影响因素进行关联,建立降解过程的数学模型,该模型可以较好地预测脉冲放电过程中废水中4-氯酚降解率及质量浓度的变化,并且能够在一定程度上反映出脉冲放电等离子体降解有机物过程的内在特性。
Mathematical model of the degradation of p-chlorophenol in aqueous solution by pulsed high-voltage discharge plasma was established through relating the main influence factors of degradation process to the organic pollutant degradation rate with dimensionless method. The model can predict very well the change of p-chlorophenol concentration in the pulsed high-voltage discharge, and reveal in some degree the nature of degradation by pulsed high-voltage discharge plasma.
出处
《化学工程》
CAS
CSCD
北大核心
2006年第1期58-61,共4页
Chemical Engineering(China)
关键词
高压脉冲放电
降解
有机污染物
无因次化数学模型
废水处理
pulsed high-voltage discharge
degradation
organic pollutant
dimensionless mathematical model wastewater treatment