摘要 电能质量检测是电能质量研究的一个重要组成部分,该文提出了一种移相电能质量检测方法。该检测方法原理简单、实时性好,可对电力系统最重要的几种电能质量扰动,包括谐波、电压凹陷、电压凸起、电压波动和暂态振荡,进行检测,且方法本身没有延时,可应用于电能质量实时检测和识别系统中。该文运用大量的仿真数据和某牵引变母线电压现场采样数据对检测有效性进行了验证。 Power quality (PQ) detection is an important part in field of PQ research. A new method based on phase shift is presented for PQ disturbances detection in this paper. The proposed method is very simple and has good real-time performance. It could detect the most important PQ disturbances in power system, such as harmonics, voltage sags, voltage swells, voltage fluctuation and transient oscillation. Because the method has no time delay by itself, it is very suitable for application of real-time PQ detection and identification. A lot of simulations and some testing data of bus voltage in a driving substation are used for validity of method.
出处 《继电器》 CSCD 北大核心 2006年第3期60-62,70,共4页 Relay
关键词 电能质量 移相电能质量检测 仿真 power quality PQ detection based on phase shift simulations
  • 相关文献

参考文献9

二级参考文献27

  • 1[1]Gaouda A M,et al.Power quality detection and classification using wavelet-multiresolution signal decomposition [J].IEEE Trans. Power Delivery,1999,14(4):1469-1476.
  • 2[2]Application of multiresolution signal decomposition for monitoring short-duration variations in distribution systems[J].IEEE Trans. Power Delivery,2000,15(2):478-485.
  • 3[3]Santoso S,Powers E J,et al.Power quality disturbance waveform recognition using wavelet-based neural classifier?Part 1: Theoretical foundation, Part 2: Application [J].IEEE Trans. Power Delivery,2000,15(1):222-235.
  • 4[4]Karimi M,Mokhtari H H,Iravani R.Wavelet based on-line disturbance detection for power quality applications [J].IEEE Trans. Power Delivery,2000,15(4):1212-1220.
  • 5[5]Angrisani L,Daponte P,D'Apuzzo M.A measurement method based on the wavelet transform for power quality analysis [J].IEEE Trans. Power Delivery,1998,13(4):990-998.
  • 6[6]Poisson O,Rioual P,Meunier M.Detection and measurement of power quality disturbances using wavelet transform [J].IEEE Trans. Power Delivery,2000,15(3):1039-1044.
  • 7[7]Huang S J,et al.Application of morlet wavelets to supervise power system disturbances[J].IEEE Trans. Power Delivery,1999,14(1): 235-243.
  • 8[8]Chen Xiangxun,Measurement and classification of power quality disturbances using wavelet transform[A].Digest of Confrence on Precision Electromagnetic Measurements 2002 (IEEE IMS CPEM2002) [C].June 16-21, 2002:38-39.
  • 9[9]Chen Xiangxun,Wavelet-based detection,localization, quantification and classification of short duration power quality disturbances [A].Proceedingds of IEEE Power Engineering Society Minter Meeting 2002[C].Jan. 27-31,2002,2:931-936.
  • 10[11]Simoncell E P,et al.Shiftable multiscale transforms [J].IEEE Trans. Inf. Theory,1992,38(2):587-607.