期刊文献+

Performance of an irreversible quantum refrigeration cycle

Performance of an irreversible quantum refrigeration cycle
下载PDF
导出
摘要 A new model of a quantum refrigeration cycle composed of two adiabatic and two isomagnetic field processes is established. The working substance in the cycle consists of many non-interacting spin-1/2 systems. The performance of the cycle is investigated, based on the quantum master equation and semi-group approach. The general expressions of several important performance parameters, such as the coefficient of performance, cooling rate, and power input, are given. It is found that the coefficient of performance of this cycle is in the closest analogy to that of the classical Carnot cycle. Furthermore, at high temperatures the optimal relations of the cooling rate and the maximum cooling rate are analysed in detail. Some performance characteristic curves of the cycle are plotted, such as the cooling rate versus the maximum ratio between high and low "temperatures" of the working substances, the maximum cooling rate versus the ratio between high and low "magnetic fields" and the "temperature" ratio between high and low reservoirs. The obtained results are further generalized and discussed, so that they may be directly applied to describing the performance of the quantum refrigerator using spin-J systems as the working substance. Finally, the optimum characteristics of the quantum Carnot and Ericsson refrigeration cycles are derived by analogy. A new model of a quantum refrigeration cycle composed of two adiabatic and two isomagnetic field processes is established. The working substance in the cycle consists of many non-interacting spin-1/2 systems. The performance of the cycle is investigated, based on the quantum master equation and semi-group approach. The general expressions of several important performance parameters, such as the coefficient of performance, cooling rate, and power input, are given. It is found that the coefficient of performance of this cycle is in the closest analogy to that of the classical Carnot cycle. Furthermore, at high temperatures the optimal relations of the cooling rate and the maximum cooling rate are analysed in detail. Some performance characteristic curves of the cycle are plotted, such as the cooling rate versus the maximum ratio between high and low "temperatures" of the working substances, the maximum cooling rate versus the ratio between high and low "magnetic fields" and the "temperature" ratio between high and low reservoirs. The obtained results are further generalized and discussed, so that they may be directly applied to describing the performance of the quantum refrigerator using spin-J systems as the working substance. Finally, the optimum characteristics of the quantum Carnot and Ericsson refrigeration cycles are derived by analogy.
机构地区 Department of Physics
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第1期53-59,共7页 中国物理B(英文版)
基金 Project supported by the National Natural Science Foundation of China (Grant No 10465003) and the Natural Science Foundation of Jiangxi Province, China (Grant No 0412011).
关键词 spin systems quantum refrigeration cycle performance parameters spin systems, quantum refrigeration cycle, performance parameters
  • 相关文献

参考文献25

  • 1Sisman A and Saygin H 2001 Appl. Energy 68 367.
  • 2Sisman A and Saygin H 1999 J. Phys. D 32 664.
  • 3He J Z, Wang L, and Li J B 2005 Acta Phys. Sin. 54 24(in Chinese).
  • 4He J Z, Chen J C, and Hua B 2002 Appl. Energy 72 542.
  • 5Chen J C, He J Z and Hua B 2002 J. Phys. A Math. Gen.35 7995.
  • 6Feldmann T and Kosloff R 2000 Phys. Rev. E 61 4774.
  • 7Wu F, Chcn L G, Sun F R et al 1998 Energy Convers.Manage. 39 1161.
  • 8Kosloff R and Geva E 2000 J. Appl. Phys. 87 8093.
  • 9He J Z, Chen J C and Hua B 2002 Phys. Rev. E 65 036145-1.
  • 10Chen J C, Lin B H and Hua B 2002 J. Phys. D Appl.Phys. 35 2051.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部