摘要
介绍了70m3聚合釜的特点,对全国首例出现的内冷管泄漏问题提出了切实可行的检修方案。经检修后聚合釜运行正常。
The features of 70m^3 polymerizer were introduced. The feasible repair and examination method on the first example of leakage of inner cool tube in the whole nation were put forward. Then the operation of polymerizer was normal.
出处
《中国氯碱》
CAS
2006年第1期31-32,共2页
China Chlor-Alkali
关键词
70
m^3釜
内冷管
泄漏
70m^3 polymerizer
inner cool tube
leakage