阐述模态pushover方法的基本原理及基本步骤,结合国外应用模态pushover计算一个9层钢结构的结果进行了分析,并应用时程分析方法对设计结果进行了验证,表明这种方法在评估和设计结构时具有很高的精度。
In this paper, the basic theory and method is presented. Applying this method to an nine-story steel structure, compared the result with rigorous non-linear response history, it is demonstrated that MPA procedure is accurate enough for practical application in building evaluation and design.