期刊文献+

旋转DSA在脑动静脉畸形造影中的应用价值 被引量:1

THE CLINICAL VALUE OF ROTATING DSA IN ANGIOGRAPHY FOR CEREBRAL ARTERIOVENOUS MALFORMATION
下载PDF
导出
摘要 目的探讨旋转DSA在脑动静脉畸形造影中的临床价值。方法回顾性分析15例脑动静脉畸形传统及旋转DSA的造影影像资料。结果本组病例中,供血动脉的显示RDSA显示14例,常规造影10例;引流静脉的显示RDSA显示13例,常规造影8例;静脉窦狭窄的显示RDSA显示11例,常规造影6例。结论旋转DSA较常规DSA能更清楚地显示脑动静脉畸形的供血动脉、引流静脉、畸形血管团的特征,为临床治疗提供更多信息。 Objective To explore the clinical value of rotating DSA (RDSA) inangiography for cerebral artefiovenous malformation (CAVM). Methods The images of 15 patients with CAVM developed by traditional DSA (TDSA) and RDSA were retrospectively analyzed. Results Out of all the patients, 14 cases with blood supply arteria developed by RDSA and 10 by TDSA, 13 with draining vena developed by RDSA and 8 by TDSA, 11 with sinus venous constriction developed by RDSA but 6 by TDSA. Conclusion RDSA is better than TDSA for developing CAVM and able to provide more information for clinical therapy.
出处 《现代医院》 2005年第10期46-47,共2页 Modern Hospitals
关键词 脑动静脉畸形 旋转DSA 血管造影术 Cerebral arteriovenous malformation, Rotating DSA, Angiography
  • 相关文献

参考文献5

二级参考文献10

  • 1安东洪,杨海山,尹卫,钟朝辉.DSA三维立体电视图像制作技术研究[J].中华放射学杂志,1996,30(4):277-278. 被引量:5
  • 2Tu RK, Cohen WA, Maravilla KR, et al. Digital subtraction rotational angiography for aneurysms of the intracranial anterior circulation: injection method and optimization. AJNR Am J Neuroradiol, 1996, 17(6):1127-1136.
  • 3Fahrig R, Fox AJ, Lownie S, et al. Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results. AJNR Am J Neuroradiol, 1997, 18(8): 1507-1514.
  • 4Heautot JF, Chabert E, Gandon Y, et al. Analysis of cerelrvascular diseases by a new 3-dimensional computerised X-ray angiography systen.Ne uroradiology, 1998, 40(4): 203-209.
  • 5Anxionnat R, Bracard S, Macho J, et al. 3D angiography. Clinical interest. First applications in interventional neuroradiology. J Neuroradiol,1998, 25(4): 251-262.
  • 6Tantivatana J, Kim SJ, Chavali RV, et al. 3D angiography in evaluation of intracranial aneurysmm and arteriovenous malformation ( abstract). Intervent Neuroradiol, 1999,5( suppl 1 ) :80.
  • 7Schumacher M, Husstedt H. Accuracy of 3D angiography and 3D CTA in measurement of vessel diameter (abstract). Intervent Neuroradiol, 1999,5 (suppl 1 ): 87.
  • 8Moret J, Weill A, Piotin M, et al. Why 3D angiography has become mandatory for treatment of intracranial berry aneurysm? analysis and results over 100 aneurysms( abstract ). Intervent Neuroradiol, 1999,5 ( suppl1):64.
  • 9Bendib K, Poirier C, Croisille P, et al. Characterization of arterial stenosis using 3D imaging. Comparison of 3 imaging techniques (MRI, spiral CT and 3D DSA) and 4 display methods (MIP, SR, MPVR, VA) by using physical phantoms. J Radiol, 1999, 80(11): 1561-1567.
  • 10赵军,杨进全,吴宁,邢丽.旋转DSA应用于头颈部的技术探讨[J].中华放射学杂志,2000,34(1):29-30. 被引量:29