期刊文献+

冠脉内支架置入术治疗急性心肌梗死30例

下载PDF
导出
出处 《心脏杂志》 CAS 2006年第1期117-117,共1页 Chinese Heart Journal
  • 相关文献

参考文献3

二级参考文献26

  • 1Morice M, Serruys P, sousa J, et al. The RAVEL study: a randomized study with the sirolimus coated Bx velocity balloon-expandable stent in the treatment of patients with de novo native coronary artery lesious[abstract] [J]. Eur Heart J, 2001,22(suppl):484
  • 2Liistro F, Stankovic G, Di Mario C, et al. First clinical experience with a paclitaxel derivate- eluting polymer stent system implantation for in-stent restenosis: immediate and long-term clinical and angiographic outcome[J]. Circulation,2002,105(16):1883
  • 3Gregory CR, Huie P, Billingham ME, et al. Rapamycin inhibits arterial intimal thickening caused by both alloimmuoe and mechanical injury. Its effect on cellular, growth factor, and cytokine response in injured vessels[J]. Transplantation, 1993, 55:1409-14
  • 4Atsumoto Y, Shimokawa H, Morishige K, et al. Reduction in neointimal formation with a stent coated with multiple layers of releasable heparin in porcine coronary arteries[J]. J Cardiovasc Pharmacol, 2002,39(4):513-522.
  • 5Alt E, Haehnel I, Beilharz C, et al. Inhibition of neointima formation after experimental coranary artery stenting: a new biodegradable stent coating releasing hirudin and prostacyclin analogue iloprost[J]. Circulation, 2000,101(12):1453-1458.
  • 6Sousa JE, Costa MA, Abizaid A, et al. Lack of neoinfimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-imensional intrarascular ultrasound study[J]. Circulation, 2001,
  • 7Sousa JE, Costa MA, Abizaid A, et al. Mid-(4 months) and long-term (1 year) QCA and three-dimensional IVUS follow-up after inplantation of sirolimus- coated stents in human coronary arteries[abstract][J]. J Am Coll Cardiol, 2001,37:8A.
  • 8Rensing B, Vos J, Smits P, et al. Coronary restenosis elimination with a sirolimus eluting stent. First European human experience with six month angiographic and intrarascular ultrasonic follow-up[J]. Eur Heart J, 2001,22:2125-2130.
  • 9Heldman AW, Cheng L, Jenkins GM, et al. Paclitaxel stent coating inhibits neointimal hyperplasia at 4 weeks in a porcine model of coronary restenosis[J]. Circulation, 2001,103(18):2289-2295.
  • 10Farb A, Heller PF, Shroff S, et al. Pathological analysis of local delivery of paclitaxel via a polymer-coated stent[J]. Circulation, 2001,104(4):473-479.

共引文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部