通过分析电力变压器对散热和温升的控制要求,结合一台变压器的冷却装置更换改造实例,对新旧冷却装置降低电力变压器温升,提高负载能力,节约电能损耗等进行技术经济的对比分析。
In this paper, the requirements of power transformer to cooling and temperature rising are analyzed. As a practical example, the cooling device of a power transformer is updated. The new and old cooling devices are analyzed comparatively in reducing the transformer temperature rise, increasing the power loading and reducing the power loss.
出处
《高压电器》
CAS
CSCD
北大核心
2006年第1期58-59,62,共3页
High Voltage Apparatus
关键词
电力变压器
温升
冷却装置
改造
分析
power transformer
temperature rise
cooling device
amelioration
analysis