摘要 报道4例因主动脉瓣关闭不全行主动脉瓣置换术后的患者在术后早期出现脉搏交替现象,此时心电图为整齐的窦性心律,所记录的脉搏图形高低交替,如扪诊桡动脉时则会发现桡动脉搏数为心电图示心率的一半。患者术后均顺利恢复,显示这一现象为一过性的、良性的过程。推测这一现象出现的原因可能是术后早期主动脉瓣不再有回流,因而巨大的左室腔充盈不足,加之左室收缩力尚低。 Alternating pulse occured in the early period after AVR in 4 cases of aortic regurgitation with large left ventricular cacity(LVEDD=67-79mm). This phenomenon was recorded as following:When the heart beat was in regular sinus rhythm,the pulse wave recorded by plethysmometer and/or arterial trace showed a higher wave followed by a lower wave alternatly.The alternating pulse usually disappeared in several hours after surgery. These patients recovered from surgery uneventfully.It is believed that this phenomenon is benign in nature and dose not predict a poor prognosis.
出处 《中国胸心血管外科临床杂志》 1996年第3期129-130,共2页 Chinese Journal of Clinical Thoracic and Cardiovascular Surgery
关键词 交替脉 主动脉瓣置换 心脏外科手术 Alternating pulse Aortic valve replacement
  • 相关文献

同被引文献11

  • 1文红.心衰加重体征:交替脉[J].国外医学(护理学分册),2005,24(4):160-161. 被引量:1
  • 2萧明第,许建屏,朱晓东.人工心脏瓣膜晚期再次替换术141例分析[J].中国循环杂志,1995,10(7):407-410. 被引量:4
  • 3Fritzsche D, Eitz T, Grimmig O, et al. Home monitoring of patients after prosthetic valve replacement--a new method of early detection of valve dysfunction. Z Kardiol,2004,93: 664 - 670.
  • 4Dikmengil M, Sucu N, Aytacoglu BN, et al. Leaflet escape in a TR I bileaflet rotatable mitral valve. J Heart Valve Dis, 2004,13:638- 640.
  • 5Bharat V, Das N K, Mohanty B, et al. Reduction of mechanical heart valve thrombosis through a clinical audit. J Heart Valve Dis,2003, 12: 362 - 369.
  • 6Bortolotti U, Milano A, D' Alfonso A, et al. Evaluation of valve-related complications in patients with Sorin Bicarbon prosthesis: a seven-year experience. J Heart Valve Dis,2001,10:795 - 801.
  • 7Emery RW, Petersen RJ, Kersten TE, et al. The initial United States experience with the ATS mechanical cardiac valve prosthesis. Heart Surg Forum,2001,4:33,6 - 352.
  • 8Vitale N, Renzulli A, Agozzino L, et al. Obstnlction of mechanical mitral prostheses: analysis of pathologic findings. Ann Thorac Surg, 1997, 63:1101 - 1106.
  • 9Delay D, Pellerin M, Carrier M, et ah Immedate and long-term resuhs of valve replacement for native and prosthetic valve endocarditis. Ann Thorae Surg,2000,70:1219- 1223.
  • 10张宝仁,朱家麟,郝家骅,徐志云,梅举,孙道华,邹良建,王志农.再次瓣膜替换术64例报告[J].中华外科杂志,1997,35(6):367-370. 被引量:8