摘要 从汽轮机初凝区的存在物质着手,通过电中性与物料平衡公式推导了在NH3、CO2、HCl、CH3COOH共存时其pH值的精确计算方程式,计算了4种物质的浓度在0.1 mg/L^0.5 mg/L之间变化时初凝水滴的pH值,由10幅图形表示计算结果,并分析了初凝区的腐蚀过程机理,及应该采取的措施. The occurence of acid corrosion phenomena in low-pressure cylinder of steam turbine is much more frequent than before. Some investigations show that the corrosion is resulted from acidic gas (CO2,HCl,CH3COOH), which dissolves in nascent condensation drips. But alkaline gas(NH3) exists in steam also, so the pH value in nascent condensed drips is a key question which determines if the corrosion occurs. In order to understand the pH value how to change when NH3.CO2.HCl and CH3COOH coexist, the author has deduced a precision pH value calculating equation by electroneutrality and quality balance formula. The particular pH value in nascent condensed drips may be calculated as their concentration vary from 0.1 to 0.5 mg/L, the exact calculation results are illustrated in 10 graphics. Thereafter the corrosion process of the condensator can reasonably be interpreted and some measures for corrosion prevention are given.
出处 《腐蚀科学与防护技术》 CAS CSCD 北大核心 2006年第1期20-23,共4页 Corrosion Science and Protection Technology
基金 湖南省科技攻关项目(02GKY3084) 湖南省自然科学基金项目(01JJY3027)
关键词 初凝区 初凝水滴 分配系数 PH值 酸腐蚀 initial condensation zone nascent condensation drip distribution coefficient pH value acid corrosion
  • 相关文献

参考文献5

二级参考文献6

  • 1荀飞.Mathemalica 4实例教(Mathemalica 4 example tutorial)[M].北京:中国电力出版社(Beijing:China Electric Power P,2000.7.
  • 2Stodola J.Review of boiler water alkalinity control[A], Proceeding of 47^th international water conference(Engineers Society of Western Pennsylvania)[C]. Paper IWC-86-27,October 28,1986,Pittsburgh. PA.234-243.
  • 3Goldstrohm D D, Robertson T W. Low phosphate-low sodium hydyoxide treatment in 2600 psig boileers at salt fiver project's coronado station [A].Proceeding of 50^th Anniversary international water conference[C](Engineers Society of Western Pennsylania), Paper IWC-89-46,) October 23,1989, Pittsburgh, PA 493-503.
  • 4Goldstrohm D D,Robertson T W.Low phosphate-low sodium hydroxide treatment in 2600 psig boilers at salt river project's coronado station[A].Proceedings of 50th Anniversary International Water Conference[C].1989.493-503.
  • 5朱志平,陈向东,付爱玲.氨、硅酸、有机酸及电导率对炉水R值影响的讨论[J].长沙水电师院学报(自然科学版),1999,14(3):262-266. 被引量:5
  • 6朱志平,陈田.磷酸盐处理技术在汽包锅炉炉水调节中的应用与发展[J].长沙电力学院学报(自然科学版),2002,17(2):77-81. 被引量:6