摘要 采用离轴型准直平面波相干光装置,使用纯弯曲加载夹具,测定了碳纤维复合材料(0°、90°)、玻璃钢(径向)、定向有机玻璃(X、Y方向)板材的泊桑比值。简述了纯弯条件下板材表面的位移等高线分布规律。确认实时全息方法是一种精确而实用的试验方法。 By means of the off-axis collimated plane wave coherent optical arrangement arid a loading device by pure banding, poisson ratio values of composite plates (CFRP)lay-up 0°,90° and GFRP, radial direction) and PMMA (x, y direcLion) have been measured. A brief description is given on the distributive law of contour lines of a plate deformation by pure bending. It is sure that real time holographic method is a kind of accurate and useful testing method.
作者 朱建堂
机构地区 成都飞机公司
出处 《激光杂志》 CAS 1987年第6期374-379,共6页 Laser Journal
  • 相关文献

同被引文献2

  • 1D. McCammond,J. Motycka. Strain-ratio measurements by an interferometric device[J] 1974,Experimental Mechanics(6):225~229
  • 2D. McCammond,J. Motycka. Strain-ratio measurements by an interferometric device[J] 1974,Experimental Mechanics(6):225~229