期刊文献+

废水COD快速测定方法研究 被引量:2

Research on quick determination of COD in wastewater
下载PDF
导出
摘要 研究了用硫酸锰代替硫酸银作催化剂快速测定废水COD的一种方法———开管法,经实验研究得最佳测定条件为:消解温度165℃,消解时间12min,反应体系的酸度10.8 mol/L,硫酸锰用量10 g/L。 Quick determination of COD in wastewater using opening tube method and MnSO4 as catalyst instead of Ag2SO4 is described. The optimum determining conditions are as follows: decomposition temperature 165℃, decomposition time 12 min, acidity 10.8 mol/L, MnSO4 dosage 10 g/L. It is easy, fast, accurate and sensitive, high merit with the standard method compared This method can reduce analytical cost by using MnSO4 as catalyst instead of Ag2SO4. Many water samples can be dissociated with the method and it fits for the determination of bulky water samples.
出处 《平顶山工学院学报》 2005年第6期16-18,共3页 Journal of Pingdingshan Institute of Technology
关键词 COD快速测定 催化剂 硫酸锰 开管法 废水 COD rapid determination catalyst manganese sulfate opening tube method wastewater
  • 相关文献

参考文献3

二级参考文献10

  • 1国家环保局.水和废水监测分析方法[M].北京:中国环境科学出版社,1989.260-263.
  • 2陈弘.微波密封消解法快速测定CODcr[J].环境监测,1997,(4):19-21.
  • 3中国医学科学院卫生研究所.水质分析法[M].北京:人民卫生出版社,1972.192-195.
  • 4奚旦立 孙玉生 等.环境监测[M].北京:化学工业出版社,1991.214-232.
  • 5国家环保局科技处.我国几种工业废水治理技术研究(第三册).化学工业出版社,1998
  • 6国际标准化组织 汇编,刘振庄.水与大气质量分析方法国际标准[M]中国环境科学出版社,1990.
  • 7《水和废水监测分析方法指南》编委会,.水和废水监测分析方法指南[M]中国环境科学出版社,1989.
  • 8傅大放,邹路易,邹宗柏.不加催化剂和掩蔽剂的微波密封消解法测定COD_(Cr)[J].中国环境科学,1998,18(2):154-157. 被引量:20
  • 9张莘民,高明慧.化学需氧量的分析[J].环境化学,1989,8(2):62-69. 被引量:15
  • 10高向阳,管棣,胡运良,郑君领.微波加热快速测定环境水样中的COD_(Mn)[J].环境科学,1992,13(1):79-82. 被引量:21