汞量滴定法和分光光度法对比研究 被引量:3

Study of Comparing Mercurimetrictitration with Spectrophotometry
下载PDF
导出
摘要 同时采用汞量滴定法和分光光度法分析海洋大气中所采集的氯化物总量,并计算出氯化物的沉积速率。根据计算结果利用t检验判断这2种分析法是否一致。研究表明:在显著水平α小于0.5时,2种分析方法无明显差异。 The amount of chloride deposition was determined by and spectrophotoanetry respectively with monthly sampling in the Wannin marine atmospheric environment. From the resuits of the two analyses, the chloride deposition rate was calculated. From the calculated results, the difference between mercurimetrictitratian and spectrophotnmetry was estimated using t- verification. It was proved that the two analysis have no marked difference when ot is less than 0.5.
出处 《装备环境工程》 CAS 2005年第2期53-55,共3页 Equipment Environmental Engineering
关键词 汞量滴定法 分光光度法 氯化物沉积速率 mercurimetrietitration spectrophotometry deposition rate of chloride
  • 相关文献

参考文献4

  • 1ISO9223, Corrosion of metals and alloys-Corrosivity of atmospheres -Classification[S].
  • 2ISO9225 ,Corrosion of metals and alloys-Corrosivity of atmospheres -Measurement of pollution[S].
  • 3WJ2360-1995.兵器产品自然环境试验方法环境因素检测[S].[S].,..
  • 4.全国大气腐蚀网站操作规程:腐蚀性物质浓度监测分析方法[S].[S].,1999..