摘要 通过改变GB 1677 81的分析条件,探讨了反应时间和温度等因素对以环氧氯丙烷为分析对象时测定环氧值的准确度的影响.实验结果表明:在45℃下试样与盐酸丙酮溶液反应4 h后测得环氧氯丙烷的环氧值与理论值最接近,相对误差在0.4%以下,比国标GB 1677 81采用的分析方法带来的相对误差(6.5%以上)有明显的降低. The effects of testing conditions,i, e. reaction time and temperature,on the accuracy for determining epoxy value of epichlorohydrin were investigated in this paper. These conditions followed Chinese Standard GB1677 -81 with some appropriate improvements. Experimental results showed that, for epichlorohydrin reacting with hydrochloric acid -acetone for 4 h at 45℃ ,its epoxy value was very close to the theoretical value. The relative error of this method was below 0. 4 %, much lower than that of the testing method adopted in GB1677 -81 (above 6.5%).
出处 《武汉化工学院学报》 2006年第1期5-7,共3页 Journal of Wuhan Institute of Chemical Technology
基金 湖北省教育厅重大项目(项目编号2002z20004)
关键词 环氧值 盐酸丙酮法 环氧氯丙烷 分析误差 epoxy value hydrochloric acid - acetone solution epichlorohydrin error analysis
  • 相关文献

参考文献5

  • 1王德中.环氧树脂生产与应用[M].北京:化学工业出版社,1997..
  • 2GB1678-81.增塑剂环氧值的测定(盐酸-吡啶法)[S].[S].,..
  • 3ASTM D1652 - 97,Epoxy Content of Epoxy Resins[S].
  • 4ISO 3 0 0 1:1 9 9 9 ,Plastics ,Epoxy compounds ,Determination of Epoxy equivalent[S].
  • 5GB1677-81.增塑剂环氧值的测定(盐酸-丙酮法)[S].[S].,..