摘要
一台设计比较理想的卧式再沸器,正常运行近6年后发生严重损坏,本文分析了现场资料,提出了确切的损坏原因及教训。
Serious damage has taken place at a perfectly designed horizontal reboiler after about six years normal operation. The article analyses the data from the site.thereby raising the reason for damage and drawing lessons from the case.
关键词
再沸器
腐蚀
合成氨装置
Reboiler, Passivation film, Crevice corrosion