期刊文献+

脉动真空高压蒸汽灭菌全程报警装置的研制

Development of whole-course alarm unit for pulsating vacuum high-pressure steam sterilization
下载PDF
导出
摘要 目的:针对脉动真空高压蒸汽灭菌过程中出现膜片、胶条密封不良,门、球阀关闭不严,蒸汽气压、水压不稳等情况易导致灭菌失败。特设计一种灭菌全程报警装置,对自来水源压力、抽真空能力、灭菌计时.灭菌压力、干燥计时进行实时监测,当任一程序出现异常时,报警装置将发出报警信号,提醒消毒人员及时排除故障,使灭菌效果进一步得到保障。 Some malfunctions can make pulsating vacuum high-pressure steam sterilization fail, including incompletely sealed diaphragm and strip, improperly closed gate and ball valves, unstable steam pressure and hydraulic pressure. This paper develops a whole-course alarm unit for vacuum high-pressure steam sterilization to monitor hydraulic pressure, vacuumizing ability, sterile time, sterile pressure and drying time. When any of above parameters is out of order, the unit alarms.
出处 《医疗卫生装备》 CAS 2006年第1期90-90,92,共2页 Chinese Medical Equipment Journal
关键词 脉动真空压力 蒸汽灭菌器 报警装置 pulsating vacuum high-pressure steam sterilizer alarm unit