期刊文献+

低阻力降为核心的低温吹风气潜热集中回收系统设计总结

Sum-Up of Design of System for Centralized Recovery of Latent Heat in Low-Temperature Blown Gas with Low Pressure Drop as Core
下载PDF
导出
摘要 固定层间歇式煤气发生炉排放的低温吹风气具有较高的潜热。通过采用非预混、蓄热型、不用合成弛放气、不用排烟引风机的微正压型低阻力降系统设计技术,并配套采用专用的微正压吹风气蒸汽锅炉机组,实现了吹风气潜热的高效集中回收及热力发电,取得了可观的经济效益。 The low-temperature blown gas discharged from the fixed-bed intermittent gasifier contains high latent heat. By the design technology for a slightly positive pressure low pressure drop system, which needs no premixing, is of the regenerative type, and uses no purge gas from synthesis nor an induced draft fan, but employs an accessory special steam boiler set for slightly positive pressure blown gas, thus realizing the highly efficient centralized recovery of the latent heat in the blown gas and thermal power generation, with considerable economic benefits.
出处 《化肥工业》 CAS 2006年第1期35-40,共6页 Chemical Fertilizer Industry
关键词 吹风气 潜热 回收 总结 blown gas latent heat recovery sum-up
  • 相关文献