期刊文献+

地域划分对变频空调器SEER值的影响 被引量:4

Influence of Region Zones on SEER of Variable-Frequency Air Conditioner
下载PDF
导出
摘要 目前变频空调器在中国得到了广泛使用,故如何客观评价其能耗在当前十分重要。笔者参考美国、日本变频空调器SEER标准并结合我国气候实际情况,建议GB/7725-2002送审稿计算SEER值对我国地域进行划分。并以海信KFR-2601GW/BP变频空调器为研究对象,采用空气焓值法测试不同工况下空调器所消耗的功率和制冷能力。经过相关计算验证了地域划分会对SEER产生一定的影响,同一空调器在热带的SEER值要比在温、寒带低。 At present, variable-frequency air conditioner is widely used in China, so how to evaluate its energy consumption is very important. Based on SEER standard of USA and Japan, and combined with the actual climate condition in China, the advice of making region zones is proposed in the calculation of SEER in GB/7725-2002 in this paper. Hisense KFR-2601 GWP/BP is selected as the experimental object and air-enthalpy method is applied to measure the energy and refrigerating capacity of air conditioner at different working conditions. That region zone will yield certain influence on SEER of variable-frequency air conditioner is verified through calculation. For a same air conditioner, SEER value is lower in tropical zone than in temperate zone and frigid zone.
出处 《建筑热能通风空调》 2006年第1期43-45,共3页 Building Energy & Environment
关键词 变频空凋器 SEER 建议 地域划分 实验 variable-frequency air conditioner, SEER, advice, region zones, experiment
  • 相关文献

参考文献6

二级参考文献10

  • 1杨昭,马一太,吕灿仁.房间空调器季节性能的理论分析及改善方法[J].制冷学报,1994,16(4):7-13. 被引量:7
  • 2台湾和欣机电有限公司(译).中小型分离式可变冷媒流量系统省能技术与能源政策关系[J].冷冻空调技术杂志,1994,.
  • 3台湾和欣机电有限公司(译).冷暖系统节能发展及经济分析[J].冷冻空调技术杂志,1994,.
  • 4彦启森 赵庆珠.关于房间空调器季节能效比的实验方法与计算,节能空调器技术高级研讨班[M].,1993,4..
  • 5刘彤.SEER实验台的建立及房间空调器动态特性的实验研究.清华大学硕士学位论文[M].,1995,5..
  • 6葛去亭.房间空调器系统仿真模型研究.清华大学博士学位论文[M].,1997,5..
  • 7吴忠智,吴加林.变频器应用手册书[M].北京:机械工业出版社,1998:290~293
  • 8JISC9612—1994标准解说
  • 9清华大学热工系:有关空调器SEER的试验与计算
  • 10程志明.变频空调内部结构比较[J].制冷,1999,18(1):73-74. 被引量:2

共引文献17

同被引文献47

  • 1刘圣春,马一太,成建宏.变频型房间空调器区域性季节能效比的研究[J].制冷学报,2005,26(2):47-50. 被引量:18
  • 2奚东敏,谷波,甄伟.基于气象参数的空调器SEER计算分析软件开发[J].暖通空调,2005,35(9):110-113. 被引量:2
  • 3王文斌,李廷永,余晓明,何如,徐亮,杨帅.小型风冷热泵制冷剂最佳充注量实验研究[J].制冷与空调,2005,5(6):77-79. 被引量:4
  • 4何钦波,童明伟,龙建佑.环境工况对家用空调器性能的影响[J].流体机械,2007,35(7):57-60. 被引量:10
  • 5Alex B L, James D L, Camilla D W, et al. Cost of increased energy efficiency for residential water heater[J]. ASHRAE Trans, 2000,106(2):875-891.
  • 6Olszewski M. Economic viability of heat pump desuperheaters for supplying domestic hot water[J]. ASHRAE Trans, 1984,90(1):169-177.
  • 7Cook R E. Water storage tank size requirement for residential heat pump/air-conditioner desuperheater heat recovery[J]. ASHRAE Trans, 1990,96(2):715-719.
  • 8Shao Shuangquan, Shi Wenxing, Li Xianting, et al. A new inverter heat pump operated all year round with domestic hot water[J]. Energy Conversion and Management, 2004,45(13-14):2255-2268.
  • 9Ji Jie, Pei Gang, Chow Tintai, et al. Performance of multi-functional domestic heat-pump system[J]. Applied Energy, 2005,80(3):307-326.
  • 10Jiang Huimin, Jiang Yiqiang, Wang Yang, et al. An experimental study on a modified air conditioner with a domestic hot water supply(ACDHWS)[J]. Energy, 2006,31(12): 1789-1803.