摘要 讨论了蒸发站浓黑液管线切换中发生盲管故障的原因,提出了减少和消除盲管故障的设计方法。 The occurring of pipe plugging trouble during the heavy black liquor pipes switching of effect ⊥ in evaporation plant is discussed, and the design for reducing and eliminating the pipe plugging is proposed. In addition, the consideration of pipe line design for the media which is similar to the heavy black liquor is presented.
作者 朱全茂
出处 《中国造纸》 CAS 北大核心 2006年第2期26-28,共3页 China Pulp & Paper
关键词 蒸发站 浓黑液 管线切换 盲管故障 evaporation heavy black liquor plugging eliminate