期刊文献+

新一代动物无创血压测定仪的研制及性能检验 被引量:3

EXPLOITATION OF A NEW NONINVASIVE ANIMAL'S BLOOD PRESSURE MEASURING APPARATUS AND ITS FUNCTION CHARACTERIZATION
下载PDF
导出
摘要 目的:研制新一代“动物无创血压测定仪”。方法:本研究利用与人血压测定相似的原理,以自行开发、拥有自主知识产权的专用软件克服了动物舒张压的测定点较难精确标定的困难,成功研制出新一代“动物无创血压测定仪”。并与经典的动物有创血压测定法行同步比较。结果:在正常血压、高血压、低血压等不同情况下,两法测值极为相近,相关系数皆大于0.9。结论:本研制的新一代“动物无创血压测定仪”可作为家兔、大鼠血压无创测定的可靠方法。 Aim: To produce a new, noninvasive, animal' s blood pressure measuring apparatus. Methods: By applying the principle similar with the measurement of human blood pressure, we developed a software which knowledge property owned by this research group and solved the problems of exactly demarcating the measuring spot of diastolic pressure. The blood pressure of rabbits was measured by the novel noninvasive animal's blood pressure measuring apparatus and the classic surgical catheterizing method simultaneously. Results: The novel noninvasive animal' s blood pressure measuring apparatus was successfully set up. The measured blood pressures by this apparatus are very similar( r 〉0.9) with the values obtained from the classic, surgical eatheterizing method, no matter the blood pressures are normal, high or low. Conclusion: Our new apparatus can be a reliable method for noninvasive measurement of the blood pressure of rabbits and rats.
出处 《中国应用生理学杂志》 CAS CSCD 北大核心 2006年第1期122-124,共3页 Chinese Journal of Applied Physiology
关键词 动物 血压测定 无创 animal measurement of blood pressure nonlnvaslve
  • 相关文献

参考文献3

  • 1Whitesall S E,Hoff J B,Vollmer A P,et al.Comparison of simultaneous measurement of mouse systolic arterial blood pressure by radiotelemetry and tail-cuff methods[J].Am J Physiol Heart Circ Physiol,2004,286(6):H2408-2415.
  • 2Civantos B,Aleixandre A.Blood pressure and alpha-vascular reactivity in hypertensive rats treated with amlodipine and dietary Ca[J].Eur J Pharmacol,2004,489(1-2):101-110.
  • 3岳广平 周逸平.无创测量大鼠血压装置及应用实例[J].安徽医科大学学报,1991,26(2):144-145.

同被引文献38

  • 1胡春枝,左小梅,雷绍斌,陈雪梅.碘塞罗宁联合肠内营养对腹腔感染合并低蛋白血症患者血清T3、T4和TSH及Th17水平的影响[J].热带医学杂志,2021,21(12):1572-1575. 被引量:1
  • 2朱龙坤.动物实验用体温无线遥测系统[J].福建医学院学报,1993,27(3):270-272. 被引量:1
  • 3焦海霞,李凌,余涓,戴秀中,潘燕霞.尾套法和颈动脉法测定急性应激大鼠血压变化值的比较[J].福建医科大学学报,2006,40(4):404-405. 被引量:8
  • 4杜友爱 姜起立.健康家兔心率血压及外周阻力测定.温州医学院学报,1986,16(1):75-76.
  • 5恽时锋 李辉.24例新西兰兔心电图分析.中国兽医科技,1997,5:33-33.
  • 6Lawrence Chia-Huang Wang. Circadian body temperature ol richardson' s ground squirrel under field and laboratory conditions : A comparative radio-telemetric study [ J ]. Comparative Biochemistry and Physiology Part A : Physiology, 1972,43 ( 3 ) : 503.
  • 7Naoki Nishiura, Yoshiharu Yonezawa, Ishio Ninomiva, et al. An optical and RF telemetry drug injection control and ECG system for awake small animal studies [ J ]. IEEE Engineering in Medicine and Biology Society, 1991,13:2152-2153.
  • 8Chisato Enokawa, Yoshiharu Yonezawa, Hiromichi Maki, et al. A microcontroller-based implantable telemetry system for sympathetic nerve activity and ECG measurement [ J ]. IEEE Engineering in Medicine and Biology Society, 1997,5 : 2232 - 2234.
  • 9Yoon YH, Jung ES, Kang HK, et al. Design of Implantable Wireless Biomedical Signals Telemetry System [ J ]. IEEE Industrial Electronics Society,2004,3:2982-2986.