期刊文献+

后路椎弓根螺钉内固定结合椎体成形治疗胸腰椎骨折 被引量:14

Treatment of thoracic and lumbar fractures with posterior pedicle screw fixation and vertebroplasty
下载PDF
导出
摘要 目的 探讨应用椎弓根螺钉内固定加自固化磷酸钙人工骨(CPC)椎体成形治疗胸腰椎骨折的临床效果。方法 对38例新鲜胸腰椎骨折行椎弓根螺钉系统固定的同时,加CPC行椎体成形。结果 33例获随访5~29个月,无内固定松动及断裂,伤椎高度及脊柱生理弧度无丢失。3例发生CPC渗漏至椎管和椎间孔内,椎管内静脉丛漏2例,椎前静脉漏1例。结论 椎弓根螺钉内固定加CPC椎体成形是治疗新鲜胸腰椎骨折的一种可行方法。 Objective To study the clinical effect of thoracic and lumbar fractures treated by pedicle screw fixation and vertebroplasty with calcium phosphate cement ( CPC ). Methods 38 cases with fresh thoracic and lumbar fractures were treated with pedicle screw fixation and vertebroplasty with CPC. Results 33 were followed up for 5~29 months. No instrument looseness or breakage was found. No lesioned vertebral height or spinal curve loss occurred. 3 were complicated with epidural and neural foramina leakage of CPC, 2 with vena vertebralis posterior and 1 with vena vertebralis anterior leakage. Condusions It is a feasible way to treat thoracic and lumbar fracture with pedicle screw fixation and CPC vertebroplasty.
出处 《临床骨科杂志》 2006年第1期39-41,共3页 Journal of Clinical Orthopaedics
关键词 脊柱骨折 骨折固定术 椎体成形 spinal vertebrae fractures fracture fixation, internal vertebroplasty
  • 相关文献

参考文献6

二级参考文献29

  • 1杨惠林,唐天驷,朱国良,陈荣发,洪天禄,许立,郑祖根,王以进.钉杆角弓根内固定系统治疗胸腰椎骨折的研究[J].中华骨科杂志,1995,15(9):570-572. 被引量:91
  • 2Youssef JA, Mckinley TO, Yerby SA, et al. Characteristics of pedicle screw loading. Effect of sagittal insertion angle on intrapedicular bending moments[ J]. Spine, 1999,24( 11 ) :1077 ~ 81.
  • 3Knop C, Fabian HF, Bastian L, et al. Late results of thoracolumbar burst fractures after posterior instrumentation and transpedicular bone grafting[J]. Spine, 2001, 26( 1 ) :88 ~99.
  • 4Alanay A, Acaroglu E, Yazici M, et al. Short- segment pedicle instrumentation fractures of thoracolumbar burst fractures: does transpedicular intracorporeal grafing prevent early failure? [ J ].Spine, 2001,26(2) :213 ~7.
  • 5Denis F. Spinnal instability as defined by three-column spine concept in acute spinal trauma[J]. Clin Orthop, 1984, (189) :65 ~76.
  • 6Alvine GF, Swain JM, Asher MA. The safety and efficacy of variable screw placement(VSP) and Isola spinal implant systems for the surgical treatment of thoracolumbar burst fractures.J Bone Joint Surg(Br), 1997, 79(Suppl): 306-312.
  • 7Kramer DL, Rodgers WB, Mansfield FL. Transpedicular instrumentation and short-segment fusion of thoracolumbar fractures: a prospective study using a single instrumentation system. J Orthop Trauma, 1995, 9: 499-506.
  • 8McLain RF, Sparling E, Benson DR. Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report. J Bone Joint Surg(Am), 1993,75: 162-167.
  • 9Garfin SR, Blair B, Eismont FJ. Thoracic and upper lumbar spine injuries. In: Browner BD, Jupiter JB, Levine AM,Trafton PG, eds. Skeletal trauma. 2nd ed. Philadelphia:W.B. Saunders, 2001. 947-1034.
  • 10Knop C, Fabian HF, Bastian L, Blanth M. Fate of the transpedicular intervertebral bone graft after posterior stabilization of thoracolumbar fractures. Eur Spine J, 2002, 11:251-257.

共引文献124

同被引文献161

引证文献14

二级引证文献150

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...