摘要
研究了以SrCl2作抑制剂、NH4Cl作释放剂,用AAS法测饲料中微量铬时,共存元素不干扰测定,样品回收率为93.8%~101.0%,相对标准偏差为0.78%
It is studied when a small amount of chromium in feed is measured with the method of AAS,coexistence elements and determined with SrCl 2 as a depressor and NH 4Cl as a releasing agent.As a result,the rate of sample reclamation is 93.8%~101.0% and the relative standard deviation is 0.78%.
出处
《西南民族学院学报(自然科学版)》
1996年第2期203-205,共3页
Journal of Southwest Nationalities College(Natural Science Edition)