摘要 该文用硒、碲对锑 pH 电极进行改性,制备了锑/硒化锑 pH 电极和锑/碲化锑 pH 电极。锑/硒化锑pH 电极在 pH=2~9范围内呈线性响应,响应斜率为55 mV/pH;锑/碲化锑 pH 电极在 pH=3~7范围内呈线性响应,响应斜率为53 mV/pH。改性后的锑电极改善了原有锑 pH 电极的电位漂移特性。 Sb/Sb2Se3 and Sb/Sb2Te3 pH electrodes were prepared and their response characteristic of the electrode were studied in this paper. Sb/Sb2Se3 pH electrodes showed a linear response in the range of 2-9 pH with a response slope of 55 mV/pH. Sb/Sb2Te3 pH electrodes showed a linear response in the range of 3 -7 pH with a response slope of 53 mV/pH. The potential stability of Sb/Sb2Se3 and Sb/Sb2Te3 pH electrodes have been further improved as compared to Sb/Sb2O3 pH electrodes.
出处 《化学传感器》 CAS 2005年第4期26-28,共3页 Chemical Sensors
基金 中国工程物理研究院科学技术基金(20030548)
关键词 锑电极 PH电极 改性 Sb/Sb2O3 electrode pH Electrode improvement
  • 相关文献

参考文献9

  • 1Umezawa K, Tohda K, Lin X, et al. Expanded porphyrin incorporated solvent polymeric membrane electrodes:protonation and interaction with an analyte anion at organic/water interface as studied by optical second harmonic generation and Fourier transform infrared attenuated total reflectance spectrometry[J]. Anal. Chim.Actal., 2001,426(1): 19-32.
  • 2Han W S, Park M Y, Chung K C, et al. Potentiometric sensor for hydrogen ion based on N, N' - dialkylbenzylethylenediamine neutral carrier in a poly(vinyl chloride) membrane with polyaniline solid contact [J].Talanta, 2001, 54(1): 153 - 159.
  • 3Joung K, Jung Y H, Nam H, et al. Development of pH sensor based on aromatic polyurethane matrix[J].Microchem., 2001, 68(2/3): 115 - 120.
  • 4张建民,杨长春,石秋芝,吴强,程鹏里.电极/溶液界面pH值的现场测量[J].高等学校化学学报,2001,22(11):1901-1903. 被引量:4
  • 5鲁勖琳,袁红雁,肖丹.基于氮化钛的全固态碱性pH电极的研制[J].高等学校化学学报,2003,24(8):1400-1402. 被引量:5
  • 6Eftekhari A. pH sensor based on deposited film of lead oxide on aluminum substrate electrode[J] . Sensors and Actuators B, 2003, 88:234 - 238.
  • 7Wang M, Yao S, Madon M. A long - term stable iridium oxide pH electrode[J]. Sensors and Actuators B, 2002,81:313 -315.
  • 8Ekmekci G, Kalayci S, Somer G. A solid - state hydroxide ion selective electrode for the measurement of high pH values[J]. Sensors and Actuators B, 2004, 101:260 - 264.
  • 9Roberts E J, Fenwich F. The antimony - antimony trioxide electrode and its use as a measure of acidity[J]. J.Am. Chem. Soc.,1928,50, 2 125 -2 147.

二级参考文献3

共引文献7

同被引文献21

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部