摘要
介绍了HL-2A装置低杂波加热系统中的低压部分实时保护系统的原理和工作情况。实时保护电路工作可靠,系统低压部份响应延迟时间小于1μs。在2004年的单只速调管实验中,对波导内拉弧打火,速调管管体电流和速调管集电极过流进行了实时保护,各个保护对象都有专用的探头进行测量,其中管体电流探头精度达到0.7%。实验信号的分析表明保护系统的设计达到了实验要求,有效地保护了实验对象。
The principle and operation of the low-voltage real-time protection system for the lower hybrid current drive (LI-ICD) system on HL-2A tokamak has been presented. The real-time protection is carried out by hardware circuits which must be reliable with response time less than 1μs. The real-time protection for wave guide arcing protection, klystron body-current protection and over-current protection of ldystron collector had been realized in the LHCD experiments using single klystron in 2004. Special detector for each protected target was used .The precision of body-current detector reaches 0.7 %. The proteetion system works reliably.
出处
《核聚变与等离子体物理》
EI
CAS
CSCD
北大核心
2006年第1期27-30,共4页
Nuclear Fusion and Plasma Physics