期刊文献+

Experimental system for perfusion imaging and time-intensity processing based on ultrasound contrast agent

Experimental system for perfusion imaging and time-intensity processing based on ultrasound contrast agent
下载PDF
导出
摘要 Objective: To present a self-developed experimental system for basic studies of blood perfusion imaging and time-intensity evaluating based on ultrasound contrast agent. Methods: The experimental system performed the image reconstruction and time-intensity processing with radio frequency signals. The system was comprised of ultra-high speed hardware data acquisition interface and low computational cost algorithms. The self-made contrast agent,blood mimic phantom and capillary phantom model were used to validate the experimental system. Results: The images acquired in blood phantoms with linear-array and curve-array transducers were given. The time-intensity curves corresponding to selected region of interested from image sequence were demonstrated. It was also shown the time-intensity based decay curves and a comparison of decay of ultrasound contrast agent under different ultrasound powers. Conclusion: Several experiments resulted from two in vitro phantom models show that the experimental system can be used to basic studies of blood perfusion and further clinical studies of microvasculature perfusion. Objective: To present a self-developed experimental system for basic studies of blood perfusion imaging and time-intensity evaluating based on ultrasound contrast agent. Methods : The experimental system performed the image reconstruction and time-intensity processing with radio frequency signals. The system was comprised of ultra-high speed hardware data acquisition interface and low computational cost algorithms. The self-made contrast agent ,blood mimic phantom and capillary phantom model were used to validate the experimental system. Results: The images acquired in blood phantoms with linear-array and curve-array transducers were given. The time-intensity curves corresponding to selected region of interestsequence were demonstrated. It was also shown the time-intensity based decay curves and a decay of ultrasound contrast agent under different ultrasound powers. Conclusion: Several suited from two in vitro phantom models show that the experimental system can be used to f blood perfusion and further clinical studies of microvasculature perfusion.
出处 《Journal of Medical Colleges of PLA(China)》 CAS 2006年第1期38-41,共4页 中国人民解放军军医大学学报(英文版)
基金 Supported by the National Natural Science Foundation of China(30270404)Specialized Research Fund for the Doctoral Program of Higher Education(2003069816)
关键词 实验室 超声检查 药剂 超声强度 perfusion imaging time-intensity processing ultrasound contrast agent
  • 相关文献

参考文献6

  • 1[1]Goldberg BB,Raichen JS,Forsberg F.Ultrasound contrast agents basic principle and clinical applications[M].Martin Dunits,London,2001
  • 2[2]Eyding J,Wilkening W,Reckhardt M et al.Contrast burst depletion imaging(CODIM):A new imaging procedure and analysis method for semi-quantitative ultrasonic perfusion imaging[J].Stroke,2003; 34(1):77.
  • 3[3]Bruce M,Averkiou M Tiemann K et al.Vascular flow and perfusion imaging with ultrasound contrast agents[J].Ultrasound Med Biol,2004; 30(6):735.
  • 4[4]Rim SJ,Leong-Poi H,Lindner JR et al.Quantification of cerebral perfusion with "real-time" contrast-enhanced ultrasound[J].Circulation,2001; 104:2582.
  • 5[5]Thijssen JM,de Korte CL.Modeling ultrasound contrast measurement of blood flow and perfusion in biological tissue[J].Ultrasound Med Biol,2005; 31(2):297.
  • 6[6]Song YC,Wan MX,Wu FG et al.Ultrasonic contrast perfusion imaging approach based on RF echo decorrelation[C].Proceedings of the 6th international symposium on test and measurement.Dalin,2005,P6488.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部