期刊文献+

Biomechanical features of Poly-D,L-lactic acid (PDLLA) rods through the degradation in vitro and in vivo 被引量:1

Biomechanical features of Poly-D,L-lactic acid (PDLLA) rods through the degradation in vitro and in vivo
下载PDF
导出
摘要 Objective:To observe the changing of biomechanical features during the degradation course of poly-D,L-lactic acid (PDLLA) rods in vivo and in vitro and to evaluate its value as an internal fixation material. Methods:PDLLA rods were emerged into PBS simultaneous body fluid with constant temperature of 37 C and the rods were embedded into muscle tissue of 20 rabbits for degradation in vitro and in vivo . The rods were taken out in 2, 4, 6. 8 and 12 weeks. Biomechanical features of bending, shearing and axial compression strength, rigidity and elastic modulus were observed during the degradation course. Statistical method was used to test the changes of biomechanical parameters. Results: (1) There was similar changes of bending, compressive, shearing strength and bending, compressive and shearing rigidity of the PDLLA rods between in vivo and in vitro. (2)Bending, compressive, shearing strength decreased 33%, 18% and 43% respectively within the first stage of the degradation, and after 6 weeks of degradation, they decreased slowly. (3)Elastic modulus, bending, compressive and shearing rigidity.decreased sharply during the 6 weeks of degradation, with a drop of 22% , 39% and 30% respectively, and after 8 weeks, they decreased slowly. Even after 12 weeks of degradation, the strength of the rods was still higher than that of sponge bone. Conclusion: During the degradation of the material, the strength and rigidity of PDLLA rods can meet the need of fracture fixation of cancellous bones. Objective:To observe the changing of biomechanical features during the degradation course of poly-D,L-lactic acid (PDLLA) rods in vivo and in vitro and to evaluate its value as an internal fixation material. Methods :PDLLA rods were emerged into PBS simultaneous body fluid with constant temperature of 37℃ and the rods were embedded into muscle tissue of 20 rabbits for degradation in vitro and in vivo . The rods were taken out in 2, 4, 6, 8 and 12 weeks. Biomechanical features of bending, shearing and axial compression strength, rigidity and elastic modulus were observed during the degradation course. Statistical method was used to test the changes of biomechanical parameters. Results: (1)There was similar changes of bending, compressive, shearing strength and bending, compressive and shearing rigidity of the PDLLA rods between in vivo and in vitro. (2)Bending, compressive, shearing strength decreased 33%, 18 % and 43 % respectively within the first stage of the degradation, and after 6 weeks of degradation, they decreased slowly. (3)Elastic modulus, bending, compressive and shearing rigidity.decreased sharply during the 6 weeks of degradation, with a drop of 22%, 39% and 30% respectively, and after 8 weeks, they decreased slowly. Even after 12 weeks of degradation, the strength of the rods was still higher than that of sponge bone. Conclusion: During the degradation of the material, the strength and rigidity of PDLLA rods can meet the need of fracture fixation of cancellous bones.
出处 《Journal of Medical Colleges of PLA(China)》 CAS 2006年第1期49-54,共6页 中国人民解放军军医大学学报(英文版)
关键词 L-乳酸 营养物质 生理学 临床 poly-D,L-lactic acid absorbable internal fixation rod biomechanical features internal fixation animal test
  • 相关文献

参考文献9

  • 1[1]Cutright DE,Hunsuck EE.The repair of fractures of the orbital floor using biodegradable polylactiec acid[J].Oral Surg,1972;33:28.
  • 2[2]Rokkanen PU,Bostman O,Hirvensalo E et al.Bioabsorbable fixation in orthopaedic surgery and traumatology[J].Biomaterials,2000;21(24):2607.
  • 3[3]Bostman OM.Absorbable implants for the fixation of fractures[J].J Bone Joint Surg Am,1991;73(1):148.
  • 4[4]Juutilainen T,Patiala H,Ruuskanen M et al.Comparison of costs in ankle fractures treated with absorbable or metallic fixation devices[J].Arch Orthop Trauma Surg,1997; 116(4):204.
  • 5[5]Van der Elst M,Bramer JA,Klein CP et al.Biodegradable interlocking nails for fracture fixation[J].Clin Orthop,1998; (357):192.
  • 6[6]Vasenius J,Vainionpaa S,Vihtonen K et al.Comparison of in vitro hydrolysis,subcutaneous and intramedullary implantation to evaluate the strength retention of absorbable osteosynthesis implants[J].Biomaterials,1990; 11(7):501.
  • 7[7]Ed.R.M.Kenedi.Biomechanical characteristics of bone.Advances in Biomedical Engineering.Academic Press,London.1971:138-187.
  • 8[8]Halawa M,Lee AJ,Ling RS et al.The shear strength of trabecular bone from the femur and some factors affecting the cementbone interface[J].Acta Orthop Trauma Surg,1978;92 (1):19.
  • 9[9]Williams DF,editor.Biocompatibility of orhopedic implants,Vol.1.Boca Raton,FL:CRC,1982;11-7