摘要
本文通过对滤波器调谐、调试和测试实践中发现的问题,作了剖析.主要针对方法上的原因.作了具体的阐述,并通过对方法的优化,节省现场工作时间20%,滤波装置的调试精确度也提高达15%左右,取得的效果比效明显。
This contribution analyzes problems occurred in syntony, debugging and testing of electric filters. Due to optimization of methods operation time of 20% has been saved and about 15% debugging accuracy of the fijlters has been increased.
出处
《冶金动力》
1996年第1期14-17,共4页
Metallurgical Power
关键词
滤波器
调谐
调试
测试
优化
Filter, Syntony, Debugging, Testing, Optimization