本文介绍了拉萨电网1995年3月12日发生的系统瓦解、全网停电的重大事故,对事故原因做了深入分析,并针对事故暴露出的问题提出了在电网管理和运行中应采取的对策。
On March 12, 1995, a severe accident occurred in Lhasa power system which caused the whole power system to collapse and all the power supply to the customers interrupted.The reasons for this accident are thoroughly investigated,and some weak points in system management and operation are revealed. At last,preventivemeasures to overcome these weak points are proposed.
出处
《电网技术》
EI
CSCD
北大核心
1996年第4期61-63,65,共4页
Power System Technology
关键词
电网
拉萨市
故障
Power system accident
Protective relaying
Station service power consumption