摘要 以含主动调谐质量阻尼器(TMD)的建筑结构为研究对象,研究作用于TMD上的作动器输出力小于设计控制力时的控制方法.为了确定系统控制率,在满足线性矩阵不等式约束的前提下,通过优化控制目标函数来达到.同时,为了保证控制效果,采用了峰-能量控制器.最后,以一座六层建筑物为例来说明本文方法的可行性. The building structures with tuned mass damper (TMD) were used as research object, and a controll strategy was proposed when the output force of the TMD actuator was less than the designed controll force. The optimization method was used to search for the system control-law under the condition that the premium of the linear matrix inequalities(LMIs) was satisfied, and the peak-energy controller was adopted for assuring the control effect. Finally, an example of 6-storey building was used to illustrate the feasibility of the presented method.
出处 《动力学与控制学报》 2006年第1期69-72,共4页 Journal of Dynamics and Control
基金 江苏省自然科学基金资助项目(BK2003083)~~
关键词 饱和作动器 LMIS 峰-能量控制器 建筑结构 saturation actuator, LMIs, peak-energy controller, building structures
  • 相关文献

参考文献8

  • 1[3]Cao H,Li QS.New Control Strategies for Active Tuned Mass Damper Systems.Computer & Structures,2004,82:2341~2350
  • 2[4]Johnson EA,Voulgaris PG.Multiobjective Optimal Structural Control of the Notre Dame Building Model Benchmark.Earthquake Eng.Struct.Dyn.,1998,27:1165~1187
  • 3[5]Scherer C,Gahinet P.Multi-objective Output Feedback Control via LMI optimization.IEEE Trans.Autom.Control,1997,42(7):896~910
  • 4[6]Yang JN,Lin S,Jabbari F.Linear Multiobjective Control Strategies for Wind-Excited Buildings.J.Engineering Mechanics,2004,130(4):471~477
  • 5[7]Kim JH,Jabbari F.Actuator Saturation and Control Design for Buildings under Seismic Excitation.J.Engineering Mechanics,2002,128(4):403~412
  • 6[8]Takikao S,Takao F.Multiobjective Control via Successive Over-Bounding of Quadratic Terms.International Journal of Robust and Nonlinear Control,2005,15(8):363~381
  • 7[9]Kim JH,Jabbari F.Scheduled Controlled for Buildings under Seismic Excitation with Limited Actuator Capacity.J.Engineering Mechanics,2004,130(4):800~808
  • 8[10]Ohtori Y,Christenson RE,Spencer BF,Dyke SJ.Benchmark Control Problems for Seismically Excited Nonlinear Buildings.J.Engineering Mechanics,2004,130(4):366~384

同被引文献22

  • 1Sakai F, Takaeda S, Tamaki T. Tuned liquid column dampernew type device for suppression of building vibrations. In: Proceedings of International Conference on High-rise Buildings, Nanjing, China, 1989:926 -31.
  • 2Clark A J. Multiple passive tuned mass damper for reducing earth - quake induced building motion [ C ]. Pro 9th World Conf on Earth - quake Engrg, 1988:283 - 290.
  • 3Z. G. Yinga, Y. Q. Nib, J. M. Kob. Semi - active optimal control of linearized systems with multi - degree of freedom and application. Journal of Sound and Vibration,2005,279:373 - 388.
  • 4T. Balendra, C. M. Wang, N. Yam Control of wind - excitedtowers by active tuned liquid column damper. Engineering Structures 23 (2001) 1054 - 1067.
  • 5龙复兴,张旭,顾平,姚进.TMD—结构系统的按规范抗震设计方法[J].哈尔滨建筑大学学报,1997,30(3):1-6. 被引量:5
  • 6李桂青,邹祖军.结构控制理论及其应用[M].上海:同济大学出版社,1989.
  • 7Kelly J M. The role of damping in seismic isolation [J].Earthquake Engineering and Structural Dynamics, 1999, 28(1) :3 -20.
  • 8Ramallo J C,Johnson E A,Spencer B F. Smart base isolation systems [J]. Journal of Engineering Mechanics, 2002, 128(10) : 1088 - 1099.
  • 9Yang J N, Agrawal A K. Semi-active hybrid control systems for nonlinear buildings against near-field earthquakes[J].Journal of Engineering Structures, 2002, 24(3) :271- 280.
  • 10Overschee V P,Moor D. N4SID. subspace algorithms for the identification of combined deterministic-stochastic systems [J].Automatica, 1994, 30(1): 75- 93.

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部