摘要 The electromagnetic dam (EMD) in twin-roll strip caster was simulated with FEM. The results show that the direction and magnitude of Lorentz force distributing in the EMD changed in a period. The negative part is about 30% of the positive part, and the acting time of the negative force is about 40% of a period. In order to prevent the liquid steel from leaking efficiently, the distance between two poles should be the same from the top to the bottom of the EMD, otherwise the magnetic induction will be very small at the top and large at the bottom. The electromagnetic dam (EMD) in twin-roll strip caster was simulated with FEM. The results show that the direction and magnitude of Lorentz force distributing in the EMD changed in a period. The negative part is about 30% of the positive part, and the acting time of the negative force is about 40% of a period. In order to prevent the liquid steel from leaking efficiently, the distance between two poles should be the same from the top to the bottom of the EMD, otherwise the magnetic induction will be very small at the top and large at the bottom.
出处 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2006年第2期27-29,共3页 钢铁研究学报(英文版)
基金 ItemSponsoredbyStateKeyLaboratoryofRollingandAutomationinNortheasternUniversityandFoundationalTheoryPlanofDepartmentofEducationofChina
关键词 twin-roll strip casting numerical simulation electromagnetic dam twin-roll strip casting numerical simulation electromagnetic dam