摘要 分析了串联谐振逆变器在零电压换流模式下的换流过程,得出了器件的最佳开关时刻和吸收电容、触发脉冲的死区宽度之间的关系,提出了一种使器件工作于零电压开关(ZVS)条件时的逆变控制策略,设计了环内固定延时和环外动态延时来完成ZVS控制的逆变锁相电路,并进行了仿真和试验。结果证明了该控制策略的正确性和可行性。 The processes of series-resonant inverter under ZVS (zero voltage switching) control scheme is analyzed. The relationship among optimal switching time, absorption capacity and skip distance is obtained. A control scheme that can make the power electronic devices function under ZVS is suggested based on the analysis. The phase-lock inverter circuit is designed through in-loop constant and outer-loop dynamic time compensating. The static and dynamic results of simulation and experiments demonstrate the validity of this ZVS control scheme.
出处 《华北电力大学学报(自然科学版)》 CAS 北大核心 2006年第2期68-71,共4页 Journal of North China Electric Power University:Natural Science Edition
关键词 ZVS 串联谐振逆变器 死区时间 锁相 ZVS series-resonant inverter dead time phase-lock
  • 相关文献

参考文献10

二级参考文献19

  • 1高潮.一类改进的恒频PWM型并联谐振交流器[J].中国电机工程学报,1995,15(6):406-410. 被引量:1
  • 2张立 赵永健.现代电力电子技术[M].北京:科学出版社,1995..
  • 3三菱电机公司.第三代IGBT和智能功率模块应用手册[M].,1998..
  • 4美CDE公司.电容产品数据手册5.001-5.006[M].,1999..
  • 5[1]Bober.G et al.Qualification of IGBT’s and SIRET for High Frequency Inverter Application.Archiv.fuer Elektrotechnik,Springer-Verlag,1990:3~14.
  • 6[2]Heumann,K et al.Small loss Series Resonant Inverter.EPE Journal.1994,4(1):21~28.
  • 7Fisher R A, Ngo K D T and Kuo M H. A 500kHz, 250W DC-DC Converter with Multiple Outputs Controlled by Phase-shifted PWM and Magnetic Amplifiers[A]. Proc.High Frequency Power Conversion Conf. [C]. 1988:100--110.
  • 8Hua G C, Lee F C, and Jovanovic M M. An improved Zero-voltage-switched PWM Converter Using a Saturable Inductor[A]. Proceedings of VEPC' 91 [C], 1991 : 275-284.
  • 9Cho J G, Sabate J A and Lee F C. Novel Full Bridge Zero-Voltage-Transition PWM DC/DC Converter for High Power Applications[A]. IEEE APEC' 94 Rec [C]. 1994:143--149.
  • 10Fujita H, Akagi H. A 2MHz 2kW Voltage-source Inverter for Low-temperature Plasma Generators: Implementation of Fast Switching with a Third-order Resonant Ctrcuit[J]. IEEE Trans. on Industry Applications, 1999, 35( 1 ) :21 --27.

共引文献36

同被引文献36

引证文献4

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部