讨论了放电设备中影响原电池放电时间准确性的因素,包括电压测试、负荷电阻、计时精度及温度误差等。认为:要保证电池放电时间准确,放电设备必须定期校验,接地良好,夹具保持清洁,环境温度准确及采用真四线连接线等是必要的。
The factors of discharge equipment that affecting the veracity of primary battery discharge time were discussed. The factors include voltage testing, loading resistance, time precision and temperature errors. In order to assure the veracity of discharge time as having the discharge equipment verified regularly the environment temperature veracious, adopting the of primary batteries, the measures are essential, such and earthed well, keeping the clamp cleanly, keeping real 4-wire configuration connect, etc.