期刊文献+

基于FSEK30和FS-K3软件的噪声系数测量及误差分析

Noise factor measure and error analysis based on spectrum analyzer FSEK30 and software tool FS-K3
下载PDF
导出
摘要 详细分析了使用R&S公司的FSEK30频谱仪和FS-K3软件进行高增益器件噪声系数测量中的校准与测量误差问题。提出了在使用噪声源,采用Y系数法进行高增益器件测量中所应该注意的问题和处理的原则。其所涉及的分析思路和方法,对一般的噪声系数测量中涉及的校准和测量误差分析也具有一定的参考价值。 Noise factor measure calibration and error analysis of high gain amplifier is analyzed in detail based on spectrum analyzer FSEK30 and software tool FS-K3 made by R&S. During measure of high gain amplifier using Y Factor technique, the issue that should be paid attention to and processing principle are present. The idea and method is also available for general noise factor measure calibration and error analysis.
作者 刘枫 贺玲军
出处 《国外电子测量技术》 2006年第3期47-51,共5页 Foreign Electronic Measurement Technology
关键词 噪声系数测量 Y系数法 枝准 误差分析 noise factor measure, Y-factor, calibration, error analysis.
  • 相关文献

参考文献3

  • 1"射频和微波噪声测量基础"[Z].Application Note 57-1,Page 3.
  • 2Friis,H.T."无线电接收机的噪声系数"[Z].Proc.of the IRE,July,1944,PP.419-422.
  • 3"放大器和接收系统噪声性能描述"[Z].Sponsored by IRE subcommittee 7.9 on Noise,Proc.of the IEEE,March,1963,PP.436-442.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部