摘要
研究了采用Ag(Ⅰ)沉淀-Ni(Ⅱ)置换-EDTA滴定法准确测定可溶性氯化物中含氯量的方法。试样溶解后,先用AgNO3沉淀Cl-,沉淀经过滤,加入过量Ni(CN)42-发生置换反应,然后在pH为9.0 ̄10.0的氨性缓冲溶液中,以紫脲酸铵为指示剂,用ED TA标准溶液滴定置换出的Ni2+。测定结果的RSD<0.1%,加标回收率R=99.1%~101.2%。改进后的本法,终点现象明显、准确度高、干扰小。
The study deals with accurate method of determining chloride content in easy dissolving chloride by Ag(Ⅰ)precipitation-Ni(Ⅱ)displacement-EDTA titration. After sample is dissolved, the Cl^- is deposited by using solution of AgNO3. After this sediment is filter and excessive Ni(CN)4^2- is added, and thus, the displacement reaction have taken place. In the ammoniacal buffer solution that pH is 9.0~10.0, with murexide as the indicator and EDTA as the standard solution, displacement Ni^2+ is titrated to end point. RSD 〈 0.1%, and R is between 99.1% and 101.2%. The improved method is effective of end point, the degree of accuracy is high and with little disturbance.
出处
《非金属矿》
CAS
CSCD
北大核心
2006年第2期50-52,共3页
Non-Metallic Mines
关键词
氧化物
EDTA
置换滴定
紫脲酸铵
氯含量
测定
chloride EDTA displacement titration murexide chloride content determination