摘要 Cardiac preload is a very good index in reflecting cardiac function. End-diastolic volume indices determined by transpulmonary thermodilution(TDCOtp) and pulmonary artery thermodilution may give a better estimate of left ventricular preload than pulmonary capillary wedge pressure monitoring(PCWP) and central venous press(CVP). The PiCCO system (Pulse Contour Cardiac Output system; Pulsion Medical Systems, Munich, Germany) a newly available system, uses integrated transpulmonary thermodilution to measure the volumetric preload parameter global end-diastolic volume index (GEDVI) and includes the total volumes of cardiac atria and ventricles as well as part of the systemic vascular blood volume. Compared with conventional pressure-derived preload assessment, volumetric preload determination by the PiCCO system has been shown to better reflect left ventricular filling. The PiCCO system provides intermittent cardiac output(CO) assessment by TDCOtp, continuous CO measurement by pulse contour analysis (PCCO), and an estimation of intrathoracic blood volume (ITBV) from GEDV only by transpulmonary single indicator dilution, which should be a valuable parameter of cardiac preload. Cardiac preload is a very good index in reflecting cardiac function. End -diastolic volume indices determined by transpulmonary thermodilution(TDCOtp) and pulmonary artery thermodilution may give a better estirnate of left ventricular pie.load than pulmonary capillary wedge pressure monitoring(PCWP) and central venous press(CVP), The PiCCO system (Pulse Contour Cardiac, Output system; PuMon Medical Systems, Mnnich, Germany) a newly awlilable system, uses integrated transpulmonary thermodilution to measure the volumetric preload parameter global end -diastolic volume index (GEDVI) and includes the total volumes of cardiac atria and ventricles as well as part of the systemic vascular blood volume. Compared with conventional pressure -derived preload assessment, volumetric preload deterruination by the PiCCO system has been shown to better reflect left ventricular filling. The PiCCO system provides intermittent cardiac output (CO) assessment by TDCOtp, continuous CO measurement by pulse contour analysis (PCCO), and an estimation of intrathoracic blood volume (ITBV) from GEDV only by transpulmonary single indicator dilution, which should be a valuable parameter of cardiac preload.
出处 《国际麻醉学与复苏杂志》 CAS 2006年第1期58-60,共3页 International Journal of Anesthesiology and Resuscitation
关键词 心脏前负荷 连续心排血量 测量 肺动脉漂浮导管 脉搏 中心静脉压 左心房 临床意义 心脏功能 心脏负荷 cardiac output single transpulmonaly thermodilution technique cardiac function preload intrathoracic blood volume (ITBV)
  • 相关文献

参考文献23

  • 1Braunwald.心脏病学(第五版)[M].北京:人民卫生出版社,1999.1215.
  • 2刘大为.高级医师案头从书:危重病医学.北京:中国协和医科大学出版社,2000,70-96.
  • 3Michard F,Alaya S,Zarka V,et al.Global End-Diastolic Volume as an Indicator of Cardiac Preload in Patients With Septic Shock.Chest,2003,124:1900-1908.
  • 4Della Rocca G,Costa MG,Pompei L,et al.Continuous and intermittent cardiac output measurement:pulmonary artery catheter versus aortic transpulmonary technique.Br J Anaesth,2002,88:350 -356.
  • 5goedje O,Peyerl M,Seebauer T,et al.Central venous pressure,pulmonary capillary wedge pressure and intrathoracic blood volumes as preload indicators in cardiac surgery patients.Eur J Cardiothorac Surg,1998,13:533-540.
  • 6Della Rocca G,Costa MG,Coccia C,et al.Preload Index:Pulmonary Artery Occlusion Pressure Versus Intrathoracic Blood Volume Monitoring During Lung Transplantation.Anesth Analg,2002,95:835-843.
  • 7Sakka SG,Bredle DL,Reinhart K,et al.Comparison between intrathoracic blood volume and cardiac filling pressures in the early phase of hemodynamic instability of patients with sepsis or septic shock.J Crit Care,1999,14:78-83.
  • 8Neumann P.Extravascular lung water and intrathoracic blood volume:double versus single indicator dilution technique.Intensive Care Med,1999,25:216-219.
  • 9Mahajan A,Shabanie A,Turner J,et al.Pulse Contour Analysis for Cardiac Output Monitoring in Cardiac Surgery for Congenital Heart Disease.Anesth Analg,2003,97:1283-1288.
  • 10Bottiger BW,Sinner B,Motsch J,et al.Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation.Anaesthesia,1997,52:207-214.