期刊文献+

生物组织分布阻抗测量装置的研制 被引量:2

An Instrument for the Measurement of Intra-and Extra-cellular Fluid Distribution by Electrical Bio-impedance Method
原文传递
导出
摘要 根据Cole-Cole阻抗圆图、生物组织RC三元件等效电路模型和频散理论,成功地设计了一套用于测量肢体和脑神经细胞内外液分布阻抗的测量装置。整个测量装置在8031单片机的控制下,能够自动实现频率切换、数据采集和处理、结果显示和打印等功能,并采用软件方法实现自调零和系统校正。为确保被测者的安全,本装置还采用光耦合器件和DC/DC变换器进行电隔离,激励电流幅值调在100μA附近。 Based on Cole-Cole impedance locus plot, RC three elements equivalent circuit model and dispersion theory, an impedance measuring instrument for measuring the intra-and extra-cellular fluid distribution of human limbs and blain nerves has been designed. The whole system is controlled by 8031 single-chip microcomputer. It can automatically realize frequency change, deta collecting and processing , result displaying and printing. The software method is adopted for zero-compensation and system calibration. To ensure the safety, the optical couplers and DC/DC convertor are adopted for electrical isolation. The exiting current is in the order of 100 μA.
作者 唐敏
出处 《重庆师范学院学报(自然科学版)》 1996年第1期39-46,共8页 Journal of Chongqing Normal University(Natural Science Edition)
基金 重庄市科委资助
关键词 细胞内外液 生物阻抗 频散 生物组织 intra-and extra-cellular fluid, bio-impedance, dispersion