玻璃纤维聚合物加固混凝土柱抗震性能研究 被引量:8

Investigation on seismic-resistance behavior of concrete columns strengthened with GFRP
下载PDF
导出
摘要 为了研究外粘玻璃纤维布加固震损柱的抗震性能,共有11根柱进行了低周反复荷载试验,其中3根在原始状态下进行试验以确定其破坏模式,另8根柱预裂后粘贴玻璃纤维布进行修补加固后进行试验.试验结果表明,未加固柱的强度和延性都比较低,加固后柱的强度、变形能力以及耗能能力均明显改善.在试验研究的基础上,本文作者提出了加固柱目标抗震延性系数的计算方法,试验结果和计算结果基本吻合. To study the seismic-resistance behavior of reinforced concrete columns retrofitted with GFRP sheets, eleven RC columns were tested under cyclic lateral load and constant axial load. Three columns were tested on the "as built" condition to investigate the failure modes under different degrees of axial loads. Eight other columns were pre-damaged and tested after retrofitted with bonding GFRP sheets. The "as built" columns suffered failures at low strength and displacement ductility. Strength, displacement and energy dissipating capacity of the retrofitted columns were improved significantly. Based on reported test results for GFRP-strengthened concrete, one calculation method of displacement ductility factor is provided, and approximate agreement between test and theoretical results is achieved.
出处 《哈尔滨工业大学学报》 EI CAS CSCD 北大核心 2006年第3期427-431,467,共6页 Journal of Harbin Institute of Technology
基金 教育部高等学校博士学科点专项科研基金资助研究项目(20010141017) 中国博士后科研基金资助项目(20040350492) 上海市博士后科研资助计划项目(2004)
关键词 钢筋混凝土柱 玻璃纤维聚合物 加固 抗震性能 reinforced concrete column glass fiber reinforced polymer retrofit earthquake-resistance
  • 相关文献

参考文献8

  • 1中华人民共和国国家标准.建筑抗震设计规范(GB50011-2001)[S].
  • 2中华人民共和国国家标准.混凝土结构设计规范(GB50010-2002)[S].
  • 3FENG M Q,BAHNG E Y.Damage assessment of jacketed RC columns using vibration tests[J].J of Structural Engineering,1999,125 (3):265-271.
  • 4SHEIKH S A,YAU G.Seismic behavior of concrete columns confined with steel and fiber-reinforced polymers[J].ACI Structural Journal,2002,99 (1):72-80.
  • 5PANTELIDES C P,GERGELY J,REAVELEY L D,et al.Retrofit of RC bridge pier with CFRP advanced composites[J].J of Structural Engineering,1999,125(10):1094-1099.
  • 6赵树红,叶列平,张轲,岳清瑞.碳纤维布对混凝土柱抗震加固的试验分析[J].建筑结构,2001,31(12):17-19. 被引量:17
  • 7吴刚,吕志涛,蒋剑彪.碳纤维布加固钢筋混凝土柱抗震性能的试验研究[J].建筑结构,2002,32(10):42-45. 被引量:34
  • 8翁义军 沈聚敏 等.复合箍对钢筋混凝土柱延性的改善[J].建筑结构学报,1985,6(4).