摘要
接力器在水轮机导水机构中起着转换和传递动力的重要作用。安康水电厂四号水轮发电机组接力器由于多种原因产生导管拉伤现象,影响了机组的安全与稳定运行。本文论述了对导管拉伤情况的测试与分析,并经过在大修中的正确处理,使接力器的运行状况得到明显改善。
The servomotor is important to ttansmt dynamic in the operating mechanism of wicketgate.The servomotor pilot tube of the fourth unit was damaged by a lot causes in Ankang hydropowerplant.So that it affected the unit smoothing rnning. In this paper, the test and analysis as well as re medial measure about the servomotor are described.
出处
《陕西水力发电》
1996年第2期29-32,37,共5页
Journal of Shaanxi Water Power